Back to Journals » International Journal of Women's Health » Volume 13

Uterocervical Angle and Cervical Length as a Tool to Predict Preterm Birth in Threatened Preterm Labor

Authors Luechathananon S, Songthamwat M, Chaiyarach S

Received 25 September 2020

Accepted for publication 15 December 2020

Published 3 February 2021 Volume 2021:13 Pages 153—159

DOI https://doi.org/10.2147/IJWH.S283132

Checked for plagiarism Yes

Review by Single anonymous peer review

Peer reviewer comments 3

Editor who approved publication: Professor Elie Al-Chaer


Sireethorn Luechathananon,1 Metha Songthamwat,2 Sukanya Chaiyarach1

1Department of Obstetrics and Gynaecology, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand; 2Department of Obstetrics and Gynaecology, Udonthani Hospital, Udon Thani, Thailand

Correspondence: Sukanya Chaiyarach Email sukanyatanoorat@hotmail.com

Objective: To evaluate the diagnostic performance of uterocervical angle (UCA) and UCA with cervical length (CL) in predicting preterm delivery in threatened preterm labor.
Methods: A multicenter prospective observational cohort study was conducted in 160 pregnant women having threatened preterm labor at Srinagarind and Udonthani Hospitals in Thailand between March 2019 and June 2020. Researchers measured UCA and CL by transvaginal ultrasonography. Medical records were reviewed for patient characteristics, and patients were followed up until the date of delivery to assess for the outcome of preterm birth. The cut-off point of UCA was determined from receiver operating characteristic curve analysis. The sensitivity, specificity, likelihood ratio, positive and negative predictive values (PPV and NPV) of UCA and of UCA with CL for predicting preterm birth were determined.
Results: The incidence of preterm birth in women having threatened preterm labor was 27%. The sensitivity, specificity, PPV and NPV of UCA ≥ 110.97 degrees for predicting preterm birth were 65.1%, 43.6%, 29.8% and 77.3%, respectively. The sensitivity, specificity, PPV and NPV of UCA ≥ 110.97 degrees with CL < 3.4 centimeters for predicting preterm birth were 48.8%, 68.4%, 36.2% and 78.4%. The specificity and NPV of UCA with CL were higher than for UCA alone.
Conclusion: With adequate sensitivity and high NPV, UCA by TVS can be supplemented with CL measurement in threatened preterm labor management to increase the diagnostic performance for predicting preterm birth.

Keywords: uterocervical angle, cervical length, preterm birth, threatened preterm labor

Creative Commons License This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.