Evaluation of the Hydrophilic, Cohesive, and Physical Properties of Eight Hyaluronic Acid Fillers: Clinical Implications of Gel Differentiation

Authors Enright KM, Weiner SF, Durairaj KK , Gilardino MS, Nikolis A 

Received 25 October 2023

Accepted for publication 25 December 2023

Published 12 January 2024 Volume 2024:17 Pages 89—101

DOI https://doi.org/10.2147/CCID.S446429

Checked for plagiarism Yes

Review by Single anonymous peer review

Peer reviewer comments 2

Editor who approved publication: Dr Jeffrey Weinberg



Kaitlyn M Enright,1 Steven F Weiner,2 Kalpna K Durairaj,3 Mirko S Gilardino,4 Andreas Nikolis5

1Clinical Research Unit, Erevna Innovations Inc, Westmount, Quebec, Canada; 2The Aesthetic Clinique, New York, NY, USA; 3Beauty by Dr. Kay, Pasadena, CA, USA; 4Division of Plastic Surgery, McGill University, Montreal, Quebec, Canada; 5Clinical Research Unit, Erevna Innovations Inc, Westmount, Quebec, Canada; Department of Plastic Surgery, McGill University, Montreal, Quebec, Canada

Correspondence: Kaitlyn M Enright, Clinical Research Unit, Erevna Innovations Inc, 376 Victoria Ave., Suite 400A, Westmount, QC, H3Z 1C3, Canada, Tel +1 514-488-0163 Ext 256, Email [email protected]

Background: Hyaluronic acid (HA) fillers are used to treat an array of aesthetic indications. Proper filler selection is paramount for successful patient outcomes. However, many important physiochemical and physical properties that impact HA gel behavior remain undefined.
Purpose: To evaluate the hydrophilicity, cohesivity and particle size of eight commercial HA fillers manufactured by either Non-Animal Stabilized Hyaluronic Acid (NASHA) or Optimal Balance Technology (OBT) techniques.
Methods and Materials: Three individual in vitro experiments were performed to assess HA swelling capacity, cohesion, and particle size. Image analyses, blinded evaluation using the Gavard-Sundaram Cohesivity Scale, and laser diffraction technology were utilized, respectively.
Results: Compared to fillers manufactured with NASHA technology, OBT products demonstrated greater swelling capacity, cohesion, and wider particle size distributions. Strong positive correlations between swelling factor, degree of cohesivity, and increasing widths of the particle size distributions were observed.
Conclusions: The hydrophilicity, cohesivity and particle size distributions vary among HA fillers manufactured with different techniques. The creation of new labels identifying products based on their unique combination of physiochemical and physical characteristics may help guide appropriate selection of HA fillers to optimize patient outcomes.

Keywords: Optimal balance technology, OBT, Non-animal stabilized hyaluronic acid, NASHA, aesthetics


Corrigendum for this paper has been published.


Introduction

For the treatment of age-related volume loss and wrinkles, the aesthetic practitioner has a myriad of hyaluronic acid (HA) fillers to choose from in their armamentarium. Perspectives on the proper selection of filler have been debated previously,1 with consensus statements and treatment guidelines continuously being developed and advanced.2–4 Various properties that help qualify the use of certain HA fillers for specific indications have been defined and measured.5 Gel strength/firmness [G prime (G’)] has been shown previously to differentiate between gels,6,7 but other important features of HA include its hydrophilicity (ability to retain water), cohesivity (the force of attraction that holds molecules of a given substance together), and physical characteristics [eg, particle size (mean and distribution), shape]. The aim of the present study was to evaluate these properties in eight commercially available HA fillers, manufactured by two different methods [Non-Animal Stabilized Hyaluronic Acid (NASHA) and Optimal Balance Technology (OBT)]. In addition, the findings of this study aim to provide injectors with a scientific rationale for differentiating fillers based on their physiochemical and physical characteristics.

Methods

Three related experiments were performed using HA fillers from several batches. Each experiment was performed twice, with tests conducted in a private practice and university laboratories.

Simulating in vivo HA Hydration

In the first experiment, eight fillers (Table 1) commercially available in the Canadian market were loaded from their prepackaged syringes into 10 mL test tubes, and diluted with normal saline in a 1:7 ratio. To ensure sufficient hydration, 3.5 mL of saline was first delivered to the test tube, followed by 1mL of HA, and topped with another 3.5 mL of saline. The low HA to saline ratio was carefully selected to ensure there would be sufficient space in the tube to visualize the interface between the saline and hydrated HA. Additionally, this dilution factor was supported by previously published work that demonstrated certain fillers absorbed up to 400% of their weight in water.8,9 The volumes used were also limited by the size of the 10 mL vials. The tubes were sealed with a screw top, inverted ten times, then left to rest at room temperature (21.5–23.5° C) for seven days. The room temperature was checked once daily. After the seven-day incubation period, the test tubes were centrifuged for five minutes at 10,000 revolutions per minute (rpm). This allowed the denser hydrated HA to pass to the bottom of the test tube, while the unabsorbed saline rose to the top. The centrifugation configuration was carefully selected using rationale from two previous studies. The first study was an experiment conducted by Goodman et al,8 which allowed for approximately 3500rpm for ten minutes (total of 35,000 revolutions). In a later study, investigators rotated the centrifuge at 1200rpm for twelve minutes (total of 14,400 revolutions) and raised concerns that longer durations could potentially compress the saline out of the hydrated HA.10 To ensure our results could be compared to these earlier works and account for the aforementioned concerns regarding the potential compression of the sample, we arbitrarily reduced the centrifuging time to five minutes since our centrifuge rotated at the same speed as that used in the first paper (total of 17,500 revolutions). After the centrifugation was completed, 10 μL of blue dye (DipQuick counter stain # 3) was gently pipetted onto the top surface of the sample. Its diffusion to the interface between the saline and the hydrated HA created a demarcation line. After approximately 90 minutes, two-dimensional photographs were captured to illustrate the saline-hydrated HA interface and used for analyses (Figure 1). The swelling capabilities of each HA were quantified based on the percent increase in volume from the original 1 mL deposited into the vial, as well as the swelling factor [defined as the maximum capacity to take up additional fluid at equilibrium],11,12 determined as final mL/g and calculated by V7/V1, where V1 is the initial volume of the gel at Day 1 and V7 is the volume of the fully swollen gel at Day 7. For statistical analysis, correlations between swelling capability and other physiochemical and physical properties were investigated.

Figure 1 Results of Experiment 1 (hydration test). The swelling capacity of each of the eight hyaluronic acid gels (AH) was evaluated based on the difference between the original volume (1mL; black demarcation line on the experimental vials; for reference, 1mL of each product is also depicted in the vial to the right of each sample) and the volume of expanded gel (indicated by the yellow line). The swelling capacity of each filler is thereby reflected by the space between the yellow and black lines and was calculated as the percent increase in volume from baseline (Table 2).

Abbreviations: HA-SBV, Restylane Skinboosters Vital; HA-L, Restylane Lyft; HA-V, Restylane Volume; HA-D, Restylane Defyne; HA-K, Restylane Kysse; HA-R, Restylane Refyne; HA-REST, Restylane-L; HA-SBVL, Restylane Skinboosters Vital Light.

Notes: Samples are displayed from least absorbency (left, top row) to most absorbency (right, bottom row). Samples wherein the black line lays above or near the yellow line have low (samples AD) swelling capabilities and those wherein the yellow line lays above the black line have greater swelling capabilities (samples E to (H).

Table 1 Summary Descriptions of the Eight Hyaluronic Acid Fillers Evaluated in the Present Experiments

Table 2 Results from All Three Experiments

Evaluation of Cohesivity

A cohesivity assay was performed under standardized testing conditions, including a room temperature between 22.5–23.5° C. First, 0.1 mL of blue dye (DipQuick counter stain # 3) was added as a coloring agent to 1 mL of HA gel, using a Luer Lock. After mixing the HA and dye for 1 minute, samples were loaded into an 800-mL glass beaker containing 370 mL of distilled water and a 2 cm magnetic bar stirrer, from a fixed height of 2 cm above the water surface. Each sample was loaded using the needle provided in the manufacturer’s packaging. The gel and water mixture was stirred at a constant rotational frequency of 160 rpm. Standardized digital images were collected 90 seconds after complete extrusion of each sample into the beaker and commencement of magnetic stirring. The cohesivity of each specimen was assessed visually from these images, defined as the ratio of intact to dispersed gel. Two independent raters blinded to product selection graded all imagery, based on the five-point visual Gavard-Sundaram Cohesivity Scale (GSCS). Both raters were physician-injectors with over ten years of experience using the products under evaluation. The GSCS rates cohesivity using criteria ranging from fully dispersed (1) to fully cohesive (5).22 A third independent and blinded rater resolved any discrepancies.

Evaluation of Particle Size and Shape

The FLOWSYNC (Microtrac MRB, Pennsylvania, USA) hybrid device was used to perform the particle size and shape analyses, using tri-laser diffraction/light scattering and image analysis measurements. For characterising particle size, the FLOWSYNC reports three values: i) “MA” is the mean diameter of the area distribution, ii) “MV” is the mean diameter of the volume distribution, and iii) “MN” is the mean diameter of the number distribution. In case of conflicting data, it was decided a priori that our discussion would focus primarily on the values of MA, given this was the most relevant parameter to our analysis. Nonetheless, all collected values are reported (Table 1). For sample preparation, 0.2 mL of each filler was loaded into a 10 mL vial using the needle provided in the manufacturer’s packaging. Two millilitres of distilled water was added to each vial before samples were pipetted into FLOWSYNC’s water bath, prefilled with carrier fluid (200 mL distilled water). The FLOWSYNC’s automated filling, de-aerating, pre-circulating, and circulating operations were used to ensure consistency and repeatability of samples. Wet operation settings included: Number of rinses: 1; Flow rate: 55%; De-aeration cycles: 3; Ultrasonic power (W): 40%; Ultrasonic time: 60 seconds. During the analysis, particles flowing in the system’s stream were backlit by a high-speed strobe light and photographed by a high-resolution digital camera. The subsequent particle size and shape analyses were conducted using the system’s internal hardware (Microtrac FLOWSYNC; Leeds & Northrup, St. Petersburg, FL).

Correlations Between Physiochemical and Physical Properties

The potential correlations between swelling factor, cohesivity, and particle size were investigated.

Results

Hydrating HA

Based on the findings of Experiment 1, the following HA fillers did not expand as they bound water: Restylane-L (HAREST), Restylane Skinboosters Vital Light (HASBVL), Restylane Skinboosters Vital (HASBV), Restylane Lyft (HAL) (Figure 1, parts A-D). Each of these fillers were manufactured using NASHA technology. The fillers that did expand (swell) as they bound water included HAL, Restylane Defyne (HAD), Restylane Volume (HAV), Restylane Kysse (HAK), and Restylane Refyne (HAR) (Figure 1, parts E-H). Except for HAL, all of these fillers were manufactured using OBT technology. HAL was the only NASHA product that displayed a positive swelling capacity, and of note, it is a large-particle HA. The swelling factor (mL/g) and capacity (%) of each filler is displayed in Table 2. Products with a swelling factor between 1 and 2 mL/g resulted in negligible swelling capacities (ie, HAREST, HASBVL, HASBV). Swelling factors ranged from 1.55 to 4.1 mL/g and swelling capacities ranged from nil to 210%. Of all products evaluated, HAREST demonstrated the least potential for swelling upon hydration with saline and HAR displayed the most.

Cohesivity

The results of Experiment 2 are displayed in Figure 2. Based on Figure 2, the rank order from least to most cohesive was: HASBVL, HASBV, HAREST, HAL, HAK, HAR, HAD, HAV. Of note, HASBV and HASBVL appeared nearly identical on the cohesivity test. Based on blinded review (Table 2), samples consisted of GSCS scores of 1 (fully dispersed) and 2 (mostly dispersed). None of the samples received a cohesivity score of 3 (partially dispersed-partially cohesive), 4 (mostly cohesive), or 5 (fully cohesive). It was observed that in general, NASHA products had a lower degree of cohesivity compared to products manufactured by OBT.

Figure 2 Results of Experiment 2 (cohesivity). After being dyed blue, the cohesivity of each of the eight hyaluronic acid gels was evaluated by adding 1mL of each sample into a beaker containing distilled water and mixing for 1 minute at a constant frequency of 160 rotations per minute. Standardized digital images were collected after 90 seconds and the resulting images were evaluated by three blinded independent raters according to the Gavard-Sundaram Cohesivity Scale.22 Samples 1 to 8 are displayed by increasing degree of cohesivity.

Abbreviations: HA-SBVL, Restylane Skinboosters Vital Light; HA-SBV, Restylane Skinboosters Vital; HA-REST, Restylane-L; HA-L, Restylane Lyft; HA-K, Restylane Kysse; HA-R, Restylane Refyne; HA-D, Restylane Defyne; HA-V, Restylane Volume.

Particle Size and Shape

Each sample consisted of material containing particle sizes well within the FLOWSYNC’s range of sensitivity (ie, 0.01 μm to 4000 μm). Sphericity, which is a measure of how closely a particle resembles a perfect sphere (perfect sphericity = 1.0), was evaluated for each sample. For all samples, the sphericity values were consistently close to 1 (Table 2).

Mean Particle Size

Based on the calculation of MA, the mean particle size of each sample ranged from 138.9 to 368.9 μm (Table 2). From smallest to largest mean particle size, the following rank order was observed: HAR, HASBVL, HASBV, HAK, HAD, HAREST, HAV, HAL. Based on the mean particle size, three distinct subgroups were evident, including small (M: 144.9 μm; SD: 5.43), medium (M: 184.66 μm; SD: 4.27), and large-particle (M: 275.25 μm; SD: 81.09) HA gels (Supplemental Material 1). There was no statistically significant association between manufacturing technology and mean particle size (p > 0.05), and the 95% confidence interval for both products significantly overlapped (NASHA = 115.71 to 295.88; OBT = 124.39 to 241.90). Based on the findings displayed in Table 2 and Supplemental Material 1, the following observations were noted:

  • HASBV and HASBVL appeared similar in size
  • HAR (small) and HAL (large) were on opposite ends of the particle size spectrum
  • HAK, HAD, and HAREST were of moderate particle size
  • In addition to HAL, HAV consisted of relatively large particles

Particle Size Range

HASBVL, HASBV, HAD, HAREST, and HAL displayed a narrow range of particle sizes and HAR, HAK, and HAV displayed comparatively wider ranges. In general, products manufactured with OBT resulted in samples with a wider range of particle sizes, compared to those manufactured with NASHA. Of all samples, HAK displayed the widest range of particle sizes (Supplemental Material 2).

Particle Size Distributions

The particle size distributions are displayed in Figure 3. A simple linear regression was calculated to predict percent (%) pass, based on product and sieve size, b(product) = 0.007, b(sieve) = 0.813; t(2) = 2.925, p = 0.004. A significant regression equation was found [F(2, 657) = 640.856, p < 0.001, with an R2 of 0.661, indicating that the regression model was better at predicting the % pass than the mean alone (ANOVA p < 0.001). Although all samples contained variations of particle sizes, the distributions were far from normally distributed, and all samples displayed one or more clear peaks.

A summary of findings comparing products manufactured with NASHA versus OBT is depicted in Supplemental Material 3. Based on Experiments 1 through 3, it was concluded that NASHA has a low propensity for swelling, as well as a low degree of cohesivity. Conversely, OBT produces products with a higher propensity for swelling and a moderate level of cohesivity. Both methods of manufacturing resulted in HA products consisting of a range of particle sizes (ie, 138.9 to 368.9 μm).

Figure 3 Based on the mean particle size (MA), three distinct subgroups were evident among the nine hyaluronic acid fillers evaluated. This included small (black square), medium (blue square), and large-particle hyaluronic acid gels (green square).

Note: MA is the mean diameter of the area distribution.

Correlations Between Physiochemical and Physical Properties

There was a strong positive correlation between swelling factor and degree of cohesivity (R2 = 0.87; Supplemental Material 4). This is visually evident by comparing Figures 1 and 2. In each Figure, the four samples presented on the top row are the same, as well as the five samples on the bottom row of each image. While there are a few deviations between Figures in the exact rank order of the samples, samples A to D in Figure 1 correspond to samples 1 to 4 in Figure 2, and samples E to H in Figure 1 correspond to samples 5 to 8 in Figure 2. Given these findings, new labels were created for each sample, based on their unique combination of swelling capacity and degree of cohesion (Table 3).

Table 3 New Alpha-Numeric Labels Created for Identifying Each Sample, Based on Their Unique Combination of Swelling Factor and Degree of Cohesion

Particle size did not correlate with swelling factor nor cohesivity (p > 0.05). However, the width of the particle size distribution (narrow versus wide) significantly correlated with both cohesivity and swelling factor (p < 0.05), with wider distributions (ie, OBT products) associated with greater cohesivity and swelling capacity.

Discussion

The findings of Experiment 1 indicate that in general, NASHA products do not have significant swelling capacities while OBT products do, which is in line with previous findings.11,12 This indicates that NASHA products have already reached the equilibrium of their swelling potential following the manufacturing process, and therefore have the lowest capacity to take up additional fluid. The only exception to this rule was the large-particle HA (HAL), although it still had less swelling capacity than all the OBT products. The maximum swelling capacity observed in this experiment was HAR, which expanded to 210% its original volume. While this increase in volume may seem large, this represents only a moderate level of swelling relative to the swelling capabilities of fillers manufactured with different technologies (eg, Vycross).8,9

In Experiment 2, the cohesivity of each of the eight HA fillers under evaluation was demonstrated. The results of this experiment support that the fillers ranged only slightly in degree of cohesivity, from being fully dispersed to partially dispersed (ie, scores of 1 and 2 on the GSCS). Compared to fillers created using different manufacturing technologies (eg, Vycross), the HA fillers evaluated did not possess a high degree of cohesion.22 Nonetheless, in general NASHA products had a lower degree of cohesivity compared to products manufactured by OBT.

When reviewing the results of the particle size analysis (Experiment 3), shape must be considered along with mean size and width of the distribution. Important parameters related to particle morphology (eg, sphericity) can provide detailed information regarding the behaviour of the HA gels,23 and these key properties can change drastically with no significant differences reported in the results of the laser diffraction (ie, mean size and size distribution). In theory, production conditions can fuse particles together and cause them to deviate from their desired spherical shape. If defective particles are produced, it may cause negative effects on the flow behavior of an HA gel during injections. Therefore, the finding that all samples contained particles with a high mean sphericity value was promising.

In the literature, typically only mean particle sizes are reported and used to classify products. However, the results of a linear regression supported that particle size distributions offer better predictive value for product identification. Furthermore, the finding that samples did not contain particles of the same size, but rather consisted of a range of particle sizes, should not be interpreted as a limitation of the product’s predictability of use or consistency in manufacturing. Instead, this should be understood as an intentional manufacturing practice. Generally speaking, harder gels with a high G’ are more difficult to inject and require a greater extrusion force during injections.24 Therefore, a variety of physicochemical modifications are necessary to facilitate injection while maintaining implant persistence, such as adding uncrosslinked HA to offset injection difficulty.25

The positive correlation between swelling factor and cohesion, as previously reported by Edsman and Öhrlund11 was confirmed by the present experiments. Using drop weight as a measure of cohesion, these investigators found an R2 value of 0.96, which was slightly higher than the present findings of R2 = 0.87. However, this is likely due to the fact that their calculation of cohesivity was based on a continuous variable (ie, weight in mg) while ours used an ordinal scale (ie, cohesivity grades). Interestingly, despite employing different methods to investigate the products’ physiochemical and physical characteristics, our findings are in agreement with each other: Cohesive products are further away from their equilibrium of swelling and therefore, possess a greater propensity for swelling. It is important to note that the swelling factor of a gel is not synonymous with tissue swelling, which is a result of trauma caused by the injection procedure. Further studies are needed to establish the correlation between a gel’s swelling factor and subsequent tissue swelling at the injection site.

The findings of these three related experiments can be used by injectors as a guide to selecting the appropriate filler, based on a marriage between the products attributes [eg, hygroscopy, particle size (mean, distribution) and shape, manufacturing technology, HA content, level of crosslinking, viscosity, cohesivity, resistance to deformation (G*), elastic modulus/gel hardness (G′), viscous modulus (G′′), phase angle (δ), tissue integration, lift capacity], treatment indications (including a consideration of anatomical location and depth of injection), and patient characteristics (eg, skin thickness, skin elasticity, degree of correction required).26–29 For example, fillers shown to absorb the least amount of water could be used in areas prone to swelling, such as the periocular area and upper lip rhytids, or they could be used for more superficial injection into the dermis (eg, HASBV, HASBVL). Moreover, as water uptake can affect an injector’s ability to sculpt and integrate HA into the tissues, the findings of this study may provide additional information regarding the necessary injection technique to employ. Strengths of the present investigation were that all fillers within the NASHA and OBT families were evaluated, methods of differentiating NASHA versus OBT were established based on swelling capacity and cohesivity, and novel correlations were observed.

Cautions and Limitations

  1. Considering all three experiments were conducted in vitro, the study design has inherent limitations. For example, this study did not take into consideration the effects of anatomy, shear stress, compression, nor tissue integration on the fillers. Moreover, although we observed some level of HA degradation following the 7-day hydration period, further changes due to breakdown of the products would likely be observed with extended periods of observation. HA degradation in vivo is largely determined by the enzymatic activity of fibroblasts, which shorten the HA chains and are subsequently ingested by fibroblasts, macrophages and keratinocytes, in addition to the actions of the free radicals, hyaluronidases, thermal hydrolysis, and mechanical stress.30,31 Therefore, the study findings may not be entirely reflective of in vivo conditions.
  2. As 9/10 of the investigated products contained 20 mg/mL of HA, this study could not evaluate the effects of varying HA concentrations with changes in water absorbency.
  3. The selected products consisted of two family of fillers (OBT and NASHA), and findings may vary with different manufacturing technologies (eg, Vycross).
  4. As particle size varied within each sample, the degree of diffusion of the dye in Experiment 1 was not consistent within the vial (eg, Figure 1, parts A-H). Therefore, the calculation of swelling capability should be interpreted by rank order rather than definite quantitative values.
    1. Moreover, although the present rank orders were consistent with the findings of Fagien et al,12 and Edsman and Öhrlund,11 these previous investigators reported greater values for the relevant swelling factors. Differences in our methodology (ie, hydration time 16 hours versus 7 days) may account for these differences.
    2. Given that greater values of swelling capacity were observed after 16 hours of hydration compared to 7 days,11,12 this may indicate that significant decreases in post-injection swelling could be expected in vivo within days of treatment, since decreases were observed by this timepoint.
  5. While the authors discuss theories pertaining to potential clinical effects of the observed morphological changes that the HA fillers underwent after a period of hydration, evidencing such processes are beyond the scope of this paper.
  6. The proper selection of an HA filler should be dependent on more than just a consideration of the physiochemical and physical properties investigated herein. Therefore, the findings of this study should be used to aid in product selection, rather than to make a definite determination.
  7. It is important to recognize that the swelling capability of a filler may not necessarily translate to tissue swelling in vivo. Therefore, choosing to inject fillers known to absorb less water does not guarantee that patients will not experience edema, as this process is affected by additional factors, such as injection technique, rate of injection, depth of injection, health/quality of the tissue, and individual propensity for swelling.12

Conclusions

Findings from the current study support the notion that HA fillers manufactured with different technologies exhibit distinct physiochemical and physical properties. For example, products manufactured with OBT were found to exhibit greater swelling potential, levels of cohesivity, and a wider range of particle sizes, compared to NASHA fillers. A strong association between swelling factor and degree of cohesion was evidenced, which enabled the development of new labels to identify HA products based on their unique physiochemical and physical characteristics. In addition to previously reported parameters (eg, G prime), these novel identifiers can be used by injectors to inform product selection and optimize patient outcomes.

Acknowledgments

The authors would like to thank Aleksandra Djuric, who assisted with conducting the particle size analyses. Relatedly, we also extend our sincerest gratitude to the Department of Materials Engineering at McGill University (Montreal, QC), where the particle size analyses were conducted.

Disclosure

Dr. Kaitlyn Enright is or has been a consultant and/or speaker for Galderma (Lausanne, Switzerland) and Merz (Frankfurt, Germany). Dr. Andreas Nikolis is or has been a consultant and/or speaker for Galderma (Lausanne, Switzerland), Merz (Frankfurt, Germany), Allergan (Dublin, Ireland) and Prollenium (Montreal, QC). Dr Steven Weiner reports grants, personal fees, and non-financial support from Galderma, outside the submitted work. Dr Kalpna Durairaj reports event speaker honorarium and clinical study partnership from Merz Pharma, event speaker honorarium and trainer honorarium from Galderma Pharma, and event speaker honorarium from Prollenium (Revanesse), during the conduct of the study. The authors report no other conflicts of interest related to this work.

References

1. John HE, Price RD. Perspectives in the selection of hyaluronic acid fillers for facial wrinkles and aging skin. Patient Prefer Adherence. 2009;3:225–230. doi:10.2147/ppa.s3183

2. Fitzgerald R, Graivier MH, Kane M, et al. Appropriate selection and application of nonsurgical facial rejuvenation agents and procedures: panel consensus recommendations. Aesthet Surg J. 2010;30(Suppl):36S–45S. doi:10.1177/1090820X10378697

3. Trevidic P, Kim HJ, Harb A, et al. Consensus recommendations on the use of hyaluronic acid-based fillers for nonsurgical nasal augmentation in Asian patients. Plast Reconstr Surg. 2022;149(2):384–394. doi:10.1097/PRS.0000000000008722

4. Sundaram H, Liew S, Signorini M, et al. Global aesthetics consensus: hyaluronic acid fillers and botulinum toxin type a-recommendations for combined treatment and optimizing outcomes in diverse patient populations. Plast Reconstr Surg. 2016;137(5):1410–1423. doi:10.1097/PRS.0000000000002119

5. Kablik J, Monheit GD, Yu L, et al. Comparative physical properties of hyaluronic acid dermal fillers. Dermatol Surg. 2009;35(Suppl 1):302–312. doi:10.1111/j.1524-4725.2008.01046.x

6. Moradi A, Shirazi A, David R. Nonsurgical chin and jawline augmentation using calcium hydroxylapatite and hyaluronic acid fillers. Facial Plast Surg. 2019;35(2):140–148. doi:10.1055/s-0039-1683854

7. Wollina U, Goldman A. Correction of tear trough deformity by hyaluronic acid soft tissue filler placement inferior to the lateral orbital thickening. Dermatol Ther. 2021;34(5):e15045. doi:10.1111/dth.15045

8. Goodman GJ, Swift A, Remington BK. Current Concepts in the Use of Voluma, Volift, and Volbella. Plast Reconstr Surg. 2015;136(5 Suppl):139S–48S. doi:10.1097/PRS.0000000000001734

9. Hee CK, Shumate GT, Narurkar V, et al. Rheological properties and in vivo performance characteristics of soft tissue fillers. Dermatol Surg. 2015;41(Suppl 1):S373–81. doi:10.1097/DSS.0000000000000536

10. Woodward J, Ranjit-Reeves R, Katz DF, et al. Comparing water absorption of food and drug administration-approved hyaluronic acid fillers. Dermatol Surg. 2021;47(9):1237–1242. doi:10.1097/DSS.0000000000003108

11. Edsman KLM, Ohrlund A. Cohesion of hyaluronic acid fillers: correlation between cohesion and other physicochemical properties. Dermatol Surg. 2018;44(4):557–562. doi:10.1097/DSS.0000000000001370

12. Fagien S, Bertucci V, von Grote E, Mashburn JH. Rheologic and physicochemical properties used to differentiate injectable hyaluronic acid filler products. Plast Reconstr Surg. 2019;143(4):707e–720e. doi:10.1097/PRS.0000000000005429

13. de la Guardia C, Virno A, Musumeci M, Bernardin A, Silberberg MB. Rheologic and physicochemical characteristics of hyaluronic acid fillers: overview and relationship to product performance. Facial Plast Surg. 2022;38(2):116–123. doi:10.1055/s-0041-1741560

14. Galderma Laboratories. Instructions for use Restylane Lyft US; 2018.

15. Galderma Laboratories. Instructions for use Restylane Defyne US; 2016.

16. Galderma Laboratories. Instructions for use Restylane Kysse; 2022.

17. Galderma Laboratories. Instruction for use Restylane Refyne; 2016.

18. Galderma Laboratories. Instruction for use Restylane Skinboosters Vital Lidocaine IFU; 2016.

19. Galderma Laboratories. Instruction for use Restylane Skinboosters Vital Light Lidocaine IFU; 2016.

20. Galderma Laboratories. Instruction for use Restylane Volyme; 2016.

21. Galderma Laboratories. Instructions for use Restylane-L US; 2023.

22. Sundaram H, Rohrich RJ, Liew S, et al. Cohesivity of hyaluronic acid fillers: development and clinical implications of a novel assay, pilot validation with a five-point grading scale, and evaluation of six U.S. Food and drug administration-approved fillers. Plast Reconstr Surg. 2015;136(4):678–686. doi:10.1097/PRS.0000000000001638

23. Park KY, Kim HK, Kim BJ. Comparative study of hyaluronic acid fillers by in vitro and in vivo testing. J Eur Acad Dermatol Venereol. 2014;28(5):565–568. doi:10.1111/jdv.12135

24. Enright KM, Sampalis J, Nikolis A. Evaluation of physician volumetric accuracy during hyaluronic acid gel injections: an observational, proof-of-concept study. J Cosmet Dermatol. 2020;19(1):61–68. doi:10.1111/jocd.12985

25. Gold M. The science and art of hyaluronic acid dermal filler use in esthetic applications. J Cosmet Dermatol. 2009;8(4):301–307. doi:10.1111/j.1473-2165.2009.00464.x

26. Cho SY, Park JW, An H, et al. Physical properties of a novel small-particle hyaluronic acid filler: in vitro, in vivo, and clinical studies. J Cosmet Dermatol. 2018;17(3):347–354. doi:10.1111/jocd.12560

27. Edsman K, Nord LI, Ohrlund A, et al. Gel properties of hyaluronic acid dermal fillers. Dermatol Surg. 2012;38(7 Pt 2):1170–1179. doi:10.1111/j.1524-4725.2012.02472.x

28. Ilyin SO, Kulichikhin VG, Malkin AY. The rheological characterisation of typical injection implants based on hyaluronic acid for contour correction. Rheol Acta. 2016;55(3):223–233. doi:10.1007/s00397-016-0913-z

29. Nikolis A, Enright KM, Lazarova D, Sampalis J. The role of clinical examination in midface volume correction using hyaluronic acid fillers: should patients be stratified by skin thickness? Aesthet Surg J Open Forum. 2020;2(1):ojaa005. doi:10.1093/asjof/ojaa005

30. Park S, Park KY, Yeo IK, et al. Investigation of the degradation-retarding effect caused by the low swelling capacity of a novel hyaluronic Acid filler developed by solid-phase crosslinking technology. Ann Dermatol. 2014;26(3):357–362. doi:10.5021/ad.2014.26.3.357

31. Stern R, Kogan G, Jedrzejas MJ, Soltes L. The many ways to cleave hyaluronan. Biotechnol Adv. 2007;25(6):537–557. doi:10.1016/j.biotechadv.2007.07.001

Creative Commons License © 2024 The Author(s). This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.