Back to Journals » Medical Devices: Evidence and Research » Volume 9

Computed tomography and magnetic resonance imaging contrast media injectors: technical feature review – what is really needed?

Authors Friebe M

Received 13 February 2016

Accepted for publication 15 March 2016

Published 15 July 2016 Volume 2016:9 Pages 231—239

DOI https://doi.org/10.2147/MDER.S106338

Checked for plagiarism Yes

Review by Single-blind

Peer reviewers approved by Dr Feng Wei

Peer reviewer comments 2

Editor who approved publication: Dr Scott Fraser

Michael Friebe

Institute of Medical Engineering, Otto-von-Guericke-University, Magdeburg, Germany

Abstract: There has been little technical innovation over the last few years for contrast media (CM) injectors that are used for diagnostic imaging (computed tomography [CT], magnetic resonance imaging [MRI], and hybrid imaging systems, such as positron emission tomography–CT or magnetic resonance–positron emission tomography) examinations. The medical need of CM for the enhancement of diagnostic images has been around for a long time, but the application of the CM into the blood stream comes with potential medical complications for the patient and requires a lot of operator experience and training. Most power injector systems that are currently used can do significantly more than what is typically required; this complexity however, adds error potential and cost. This paper focuses on the main features that CM injector systems should have and highlights the technical developments that are useful to have but which add complexity and cost, increase setup time, and require intensive training for safe use. CM injection protocols are very different between CT and MRI, with CT requiring many more variances, has a need for multiphase protocols, and requires a higher timing accuracy. A CM injector used in the MRI suite, on the other-hand, could only need a relatively time insensitive injection with a standard injection flow rate and a volume that is dependent on the patients’ weight. This would make easy and lightweight systems possible, which are able to safely and accurately perform the injection task, while allowing full MRI compatibility with relatively low cost investment and consumable costs.

Keywords: power injector, contrast media injection, injection protocols, MRI compatibility

Creative Commons License This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.

Download Article [PDF]  View Full Text [HTML][Machine readable]