Comment on: Comfort After Refitting Symptomatic Habitual Reusable Toric Lens Wearers with a New Daily Disposable Contact Lens for Astigmatism [Letter]

Authors Chaurasiya SK , Singh M , Ray R

Received 1 November 2023

Accepted for publication 14 November 2023

Published 22 November 2023 Volume 2023:17 Pages 3561—3562

DOI https://doi.org/10.2147/OPTH.S447775

Checked for plagiarism Yes

Editor who approved publication: Dr Scott Fraser



Suraj Kumar Chaurasiya,1,2 Mahendra Singh,1 Ritu Ray1

1Department of Optometry and Vision Science, CL Gupta Eye Institute, Moradabad, UP, 244001, India; 2Department of Contact Lens and Anterior Segment, CL Gupta Eye Institute, Moradabad, UP, 244001, India

Correspondence: Suraj Kumar Chaurasiya, CL Gupta Eye Institute, Ram Ganga Vihar Phase II (Extn), Moradabad, UP, 244001, India, Tel +91-8809893186, Email [email protected]


View the original paper by Dr Wan and colleagues

A Response to Letter has been published for this article.


Dear editor

We read with interest the recently published article titled “Comment on: Comfort After Refitting Symptomatic Habitual Reusable Toric Lens Wearers with a New Daily Disposable Contact Lens for Astigmatism” by Wan et al.1 We want to congratulate the authors on their excellent work. The study provides valuable insights into contact lens comfort and refitting; however, there are a few drawbacks to the study which, we believe, could be considered in a similar study in the future to improve the quality of the paper.

The study did not include a direct comparison of delefilcon A toric lenses with different lens materials, including other daily disposables. A direct comparison could provide a more comprehensive understanding of how delefilcon A toric lenses compare to other options.2

Lack of masking: Subjects were not masked to their habitual toric lenses or delefilcon A toric lenses. This lack of masking could introduce bias, as the subjects were aware of the lens they were wearing. Masking would have helped to eliminate potential biases related to the subjects’ knowledge of their lens type.3 The study did not employ randomization, as subjects were dispensed their habitual lenses first and then delefilcon A toric lenses. Randomization helps to ensure that any observed differences are not due to the order of lens wear, and it would have been beneficial to include randomization in the study design.4

The study had a relatively short follow-up period for both the habitual toric lenses and delefilcon A toric lenses (2–4 weeks). This limited follow-up period prevents conclusions being drawn about the long-term effects of refits with these lenses. Longer-term data would be valuable to assess the sustained comfort and other factors.5

Limited examination of causative factors: The study did not investigate the specific factors contributing to the improved comfort after refitting. It mentioned various possibilities, such as the lens material, replacement schedule, or the absence of contact lens cleaning solutions. A more in-depth analysis could have helped to isolate the key factors responsible for the improved comfort.6

Small sample size for certain comparisons: While the study aimed for a sample size of 85 subjects, certain comparisons, such as the assessment of mean reported hours of comfortable wear, had lower power (65%). A larger sample size would have increased the likelihood of detecting significant differences in these aspects. The study focused on symptomatic reusable toric lens wearers, and therefore, the findings may not apply to asymptomatic wearers. The conclusions are specific to this subset of contact lens wearers and may not be generalizable to the broader population.7

In conclusion, the study offers important insights into refitting symptomatic reusable toric lens wearers with delefilcon A toric lenses. However, its limitations, including the lack of direct comparisons, short follow-up, and potential biases, should be considered when interpreting the findings, and further research is needed to address these limitations and provide a more comprehensive understanding of contact lens comfort and refitting.

Disclosure

The authors report no conflicts of interest in this communication.

References

1. Wan K, Mashouf J, Hall B. Comfort after refitting symptomatic habitual reusable toric lens wearers with a new daily disposable contact lens for astigmatism. Clin Ophthalmol. 2023;17:3235–3241. doi:10.2147/OPTH.S429237

2. Schulz KF, Grimes DA. Blinding in randomised trials: hiding who got what. Lancet. 2002;359(9307):696–700. doi:10.1016/S0140-6736(02)07816-9

3. Hernán MA, Robins JM. Using big data to emulate a target trial when a randomized trial is not available. Am J Epidemiol. 2016;183(8):758–764. doi:10.1093/aje/kwv254

4. Pocock SJ, Elbourne DR. Randomized trials or observational tribulations? N Engl J Med. 2000;342(25):1907–1909. doi:10.1056/NEJM200006223422511

5. Savović J, Jones HE, Altman DG, et al. Influence of reported study design characteristics on intervention effect estimates from randomized, controlled trials. Ann Intern Med. 2012;157(6):429–438. doi:10.7326/0003-4819-157-6-201209180-00537

6. Chalmers RL, Keay L, McNally J, Kern J. Multicenter case-control study of the role of lens materials and care products on the development of corneal infiltrates. Optom Vis Sci. 2012;89(3):316–325. doi:10.1097/OPX.0b013e318240c7ff

7. Nichols JJ, Willcox MD, Bron AJ, et al. The TFOS international workshop on contact lens discomfort: executive summary. Invest Ophthalmol Vis Sci. 2013;54(11):TFOS7–TFOS13. doi:10.1167/iovs.13-13212

Creative Commons License © 2023 The Author(s). This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.