Tear osmolarity changes after use of hydroxypropyl-guar-based lubricating eye drops

Authors Ng A, Keech A, Jones L

Received 1 September 2017

Accepted for publication 9 January 2018

Published 10 April 2018 Volume 2018:12 Pages 695—700

DOI https://doi.org/10.2147/OPTH.S150587

Checked for plagiarism Yes

Review by Single-blind

Peer reviewers approved by Dr Jie Zhang

Peer reviewer comments 2

Editor who approved publication: Dr Scott Fraser


Alison Ng, Adam Keech, Lyndon Jones

Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, ON, Canada

Purpose: To evaluate tear osmolarity after using a hydroxypropyl-guar (HP-guar)-based lubricating eye drop four times daily (QID) for 3 weeks.
Methods: Thirty-one participants with dry eye disease (Ocular Surface Disease Index [OSDI] score ≥20 and tear osmolarity ≥300 mOsm/L in at least one eye) were enrolled in this prospective, dispensing, non-randomized study involving a baseline visit and 3-week follow-up. Tear osmolarity, non-invasive tear break up time (NITBUT), conjunctival hyperemia, corneal and conjunctival staining were determined at baseline. Participants were instructed to instill one drop of a HP-guar-based drop QID in each eye for 3 weeks. At the follow-up visit, the symptoms and ocular surface parameters were reassessed. At this visit, one HP-guar drop was instilled into each eye and osmolarity was measured after 15 minutes, to examine short-term changes in osmolarity.
Results: Twenty-eight participants completed the study (5M, 23F; median age 54 yrs, range 25–83 yrs). At baseline, mean OSDI score was 44.9±15.2 and mean osmolarities were 314.63±11.9/306.6±10.1 mOsm/L (worst eye [WE]/better eye [BE]). After 3 weeks, mean osmolarity reduced to 307.7±15.7/303.9±11.3 mOsm/L (WE/BE; p<0.05 and p=0.228, respectively) and mean OSDI scores reduced to 28.3±17.0 (p<0.01). A significant reduction in osmolarity was observed 15 minutes after instilling the lubricating drop (p<0.05 WE, p=0.09 BE). Significant improvements in central corneal staining (p<0.05 OU) and NITBUT (p<0.05 WE only) were observed. Reductions in conjunctival staining and hyperemia were observed, but were not significant (p>0.05).
Conclusions: A significant reduction in tear osmolarity and improvements in dry eye symptoms, corneal staining, and NITBUT were observed after 3 weeks of QID use of a HP-guar-based lubricant drop. A decrease in osmolarity was also demonstrated 15 minutes after drop instillation.

Keywords: eye drop, dry eye, osmolarity, tear film, HP-guar

Creative Commons License This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.