Back to Journals » International Journal of General Medicine » Volume 18

Methodological Considerations in AIoT-Based Stroke Rehabilitation Research [Letter]

Authors Zhang Y, Ye X

Received 21 September 2025

Accepted for publication 8 October 2025

Published 10 October 2025 Volume 2025:18 Pages 6201—6202

DOI https://doi.org/10.2147/IJGM.S569176

Checked for plagiarism Yes

Editor who approved publication: Dr Woon-Man Kung



Yue Zhang,1 Xiangming Ye2

1The Second Clinical Medical College, Zhejiang Chinese Medical University, Hangzhou, Zhejiang, People’s Republic of China; 2Department of Rehabilitation Medicine, Zhejiang Province People’s Hospital, Hangzhou, Zhejiang, People’s Republic of China

Correspondence: Xiangming Ye, Email [email protected]


View the original paper by Dr Lv and colleagues


Dear editor

We read with interest the study by Lv et al investigating AIoT-based wearable devices for stroke walking rehabilitation.1 While we appreciate the authors’ innovative approach, several methodological limitations warrant discussion to advance evidence-based implementation of wearable technology in stroke rehabilitation.

The substantial group imbalance (106 AIoT vs 671 control patients) represents a fundamental design flaw that undermines validity despite propensity score matching. This 6.3:1 ratio raises serious concerns about selection bias and external validity that cannot be adequately addressed through post-hoc statistical adjustments. Boukhennoufa et al2 specifically emphasized that such unequal sample sizes in rehabilitation technology studies introduce systematic biases that limit robustness of conclusions and hinder clinical translation.

The complete absence of cost-effectiveness analysis represents a critical limitation for clinical translation. Contemporary health technology assessment requires comprehensive economic evaluation considering direct costs, indirect costs, and opportunity costs. Boukhennoufa et al2 emphasized that rehabilitation technology research must supplement effectiveness studies with economic assessment to guide resource allocation decisions. Without economic evaluation, the study provides insufficient guidance for healthcare decision-makers and policymakers considering technology adoption.

The single-center design and one-month follow-up period fundamentally limit assessment of long-term effectiveness and multicenter reproducibility. Systematic reviews consistently show that wearable sensor studies suffer from these temporal and geographical limitations, creating evidence gaps that hinder comprehensive implementation guidelines.2 The abbreviated timeline prevents assessment of sustained benefits and technology adherence—critical factors for clinical implementation decisions.

The control group description as “routine rehabilitation training” without detailed standardization protocols prevents clear attribution of benefits to specific AIoT technology versus general increased attention and training intensity. Demers et al3 emphasized that standardized training protocols are essential to avoid attention bias in technology-assisted rehabilitation studies. This confounding makes it impossible to determine whether improvements result from specific AIoT features or enhanced overall rehabilitation engagement.

The authors inadequately address digital divide implications for real-world implementation. Gebreheat et al4 demonstrated that successful digital rehabilitation requires consideration of technological literacy, support systems, and infrastructure adequacy—factors that could significantly influence reported effectiveness outcomes.

While this study contributes preliminary evidence for AIoT-based stroke rehabilitation, the methodological limitations significantly constrain generalizability and clinical translation potential. Future research requires adequately powered balanced randomized controlled trials with comprehensive economic evaluation, multicenter designs, extended follow-up periods, and attention-matched control groups to establish robust evidence that meaningfully informs clinical practice and policy decisions.

Disclosure

The authors report no conflicts of interest in this communication.

References

1. Lv Z, Su H, Zhu M, Ou J, Wang L. Optimal treatment strategies of AIoT based wearable devices for stroke walking in the rehabilitation training of ischemic stroke patients: a real-world cohort study using propensity-score matched analysis. Int J Gen Med. 2025;18:4587–4599. doi:10.2147/IJGM.S538424

2. Boukhennoufa I, Zhai X, Utti V, Jackson J, McDonald-Maier KD. Wearable sensors and machine learning in post-stroke rehabilitation assessment: a systematic review. Biomed Signal Process Control. 2022;71:103197. doi:10.1016/j.bspc.2021.103197

3. Demers M, Cain A, Bishop L, et al. Understanding stroke survivors’ preferences regarding wearable sensor feedback on functional movement: a mixed-methods study. J Neuroeng Rehabil. 2023;20(1):146. doi:10.1186/s12984-023-01271-z

4. Gebreheat G, Goman A, Porter-Armstrong A. The use of home-based digital technology to support post-stroke upper limb rehabilitation: a scoping review. Clin Rehabil. 2024;38(1):60–71. doi:10.1177/02692155231189257

Creative Commons License © 2025 The Author(s). This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms and incorporate the Creative Commons Attribution - Non Commercial (unported, 4.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.