Back to Journals » Infection and Drug Resistance » Volume 15

Evaluation of the Performance of a Multiplex Real-Time PCR Assay for the Identification of Aspergillus, Cryptococcus neoformans, and Pneumocystis jirovecii Simultaneously from Sputum in Multicenter [Letter]

Authors Idrus HH , Sunarno

Received 4 November 2022

Accepted for publication 23 November 2022

Published 24 November 2022 Volume 2022:15 Pages 6799—6800

DOI https://doi.org/10.2147/IDR.S396184

Checked for plagiarism Yes

Editor who approved publication: Professor Suresh Antony



Hasta Handayani Idrus,* Sunarno*

Center for Biomedical Research, Research Organization for Health, National Research and Innovation Agency (BRIN), Cibinong Science Center, Bogor, West Java, Indonesia

*These authors contributed equally to this work

Correspondence: Hasta Handayani Idrus, Center for Biomedical Research, Research Organization for Health, National Research and Innovation Agency (BRIN), Genomic Building, Cibinong Science Center, Jl. Raya Bogor No. 490, Cibinong – Bogor Km. 46, Bogor, West Java, Indonesia, Email [email protected]; [email protected]


View the original paper by Dr Liu and colleagues

A Response to Letter has been published for this article.


Dear editor

We appreciate the authors who have reported their research in the “Evaluation of the Performance of a Multiplex Real-Time PCR Assay for the Identification of Aspergillus, Cryptococcus neoformans, and Pneumocystis jirovecii Simultaneously from Sputum in Multicenter”. Published in Infection and Drug Resistance 2022:15 6009–6017 This is very important information about the simultaneous identification of Aspergillus, Cryptococcus neoformans, and Pneumocystis jirovecii from sputum using real-time multiplex PCR assay and DNA sequencing methods. No cross-reactivity was detected for any bacteria or fungi. In this study, the authors report that in 40 patients, mixed infection by Aspergillus and/or Cryptococcus neoformans and/or Pneumocystis jirovecii was detected by real-time multiplex assay and the kit minimum detection limit for each of the three species was 1250 copies/mL. DNA sequencing was used as the gold standard; The performance of real-time multiplex assays to detect Aspergillus, Cryptococcus neoformans, and Pneumocystis were analyzed separately.1

In this study it was also reported that the detection performance of the real-time multiplex assay for Aspergillus, compared with DNA sequencing showed the difference between the two methods was not statistically significant, P = 0.22 > 0.05, the overall coincidence rate of the two methods was the same. However, if the purpose of this study is to see the detection performance of the real-time multiplex test, then we can compare it with the results of other studies that also examined the same bacteria with different test tools because currently there are several researchers who use multiple cross displacement amplification (MCDA) combined with a nanoparticle-based lateral flow biosensor (LFB) (MCDA-LFB), which proved fast, reliable and simple to detect the same type of bacteria.2,3

Unfortunately, this study reported different results between the multiplex real-time assay of Aspergillus terreus DNA sequencing results with negative results, and the results of the real-time multiplex test of Aspergillus spp. with positive results that make those results different.

Other studies have reported that in the case of 100 sputum samples, 20 (20%) and 15 (15%) samples were positive by MCDA-LFB and PCR methods, respectively. MCDA-LFB and traditional culture methods showed similar results. Compared with the culture method, the diagnostic accuracy of MCDA-LFB can reach 100%.4 This shows that the MCDA-LFB method has a better detection ability than the PCR method because the entire process can be controlled within 60 minutes including DNA preparation (20 minutes), MCDA reaction (35 minutes) and reporting of results (2 minutes). So it can be concluded that this method has high specificity and sensitivity in detecting bacterial isolates with sputum samples.5

Acknowledgments

We appreciated all parties that gave supports to all authors of this particular study along the long study, especially in performing the experiments, analyzing the data and preparing the article.

Disclosure

The authors report no conflicts of interest in this communication.

References

1. Liu W, Li M, Xu Y, et al. Evaluation of the performance of a multiplex real-time PCR assay for the identification from sputum in multicenter. Infect Drug Resist. 2022;15:6009–6017. doi:10.2147/IDR.S379043

2. Ma Q, Yao J, Yuan S, et al. Development of a lateral flow recombinase polymerase amplification assay for rapid and visual detection of Cryptococcus neoformans/C. gattii in cerebral spinal fluid. BMC Infect Dis. 2019;19(1):1–9. doi:10.1186/s12879-019-3744-6

3. Tay E, Chen SCA, Green W, Lopez R, Halliday CL. Development of a real-time PCR assay to identify and distinguish between Cryptococcus neoformans and Cryptococcus gattii species complexes. J Fungi. 2022;8(5):4–11. doi:10.3390/jof8050462

4. Jiang L, Li X, Gu R, Mu D. Rapid detection of Aspergillus fumigatus using multiple cross displacement amplification combined with nanoparticles-based lateral flow. Front Cell Infect Microbiol. 2021;11:1–9. doi:10.3389/fcimb.2021.622402

5. Wu Y, Wang F, Wang C, et al. Detection of Pneumocystis jirovecii and Toxoplasma gondii in patients with lung infections by a duplex qPCR assay. PLoS Negl Trop Dis. 2021;15(12):1–15. doi:10.1371/journal.pntd.0010025

Creative Commons License © 2022 The Author(s). This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.