Visual, Refractive, Functional, and Patient Satisfaction Outcomes After Implantation of a New Trifocal Diffractive Intraocular Lens [Corrigendum]
Authors Mendicute J, Lauzirika G
, Illarramendi I, Martínez-Soroa I
Received 22 March 2026
Accepted for publication 22 March 2026
Published 25 March 2026 Volume 2026:20 611159
Mendicute J, Lauzirika G, Illarramendi I, Martínez-Soroa I. Clin Ophthalmol. 2024;18:2785–2795. https://doi.org/10.2147/OPTH.S480311
After publication, the authors have identified two technical/representation errors in Figures 1 and 2 on page 2788 of the published article.
The graphs originally published in Figure 2 did not correspond to the descriptions provided in the figure legend. Specifically, Figure 2 represented monocular graphs (A–C) and binocular graphs (D–F) of cumulative visual acuity measurements at 6 months, respectively. However, the study intended to present a comparison between monocular 1-month and 6-month cumulative visual acuity outcomes. To maintain consistency with the legend the authors have replaced the incorrect graphs with the intended data sets in Figure 2.
A second discrepancy was then identified between Figure 1A and E and the corrected Figure 2A and D, which should have been identical as they represent the same cumulative eye data for monocular CDVA/UCDVA at 1 month and 6 months. Consequently, Figure 1 has been updated to reflect this correction, ensuring both graphs of Figure 1A/E and Figure 2A/D are now mathematically, visually and conceptually consistent.
The authors advise Figure 2 was always generated with original LogMAR values (without any conversion). This is the reason why Figure 1 and the corrected Figure 2 did not initially match. Furthermore, all visual acuities conversions were reviewed, and no more mismatches were found.
The correct Figures 1 and 2 are shown below.
|
Figure 1 Monocular refractive outcomes at 1-and 6-month post-op. (A–D) correspond with 1-month outcomes, and (E–H) correspond with 6-month outcomes. |
The authors confirm that these changes were due to unintentional errors during the data processing for image assembly stages. These corrections are strictly for the accuracy of visual presentation and do not alter the study’s original experimental data, findings, or clinical conclusions.
The authors sincerely apologize to the Journal and the readers for any inconvenience this error may have caused.
© 2026 The Author(s). This work is published and licensed by Dove Medical Press Limited. The
full terms of this license are available at https://www.dovepress.com/terms
and incorporate the Creative Commons Attribution
- Non Commercial (unported, 4.0) License.
By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted
without any further permission from Dove Medical Press Limited, provided the work is properly
attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.