Back to Journals » Therapeutics and Clinical Risk Management » Volume 12

Comparison of continuous epidural infusion and programmed intermittent epidural bolus in labor analgesia
Authors Lin Y, Li Q, Liu J, Yang R, Liu J
Received 7 February 2016
Accepted for publication 6 April 2016
Published 14 July 2016 Volume 2016:12 Pages 1107—1112
DOI https://doi.org/10.2147/TCRM.S106021
Checked for plagiarism Yes
Review by Single anonymous peer review
Peer reviewer comments 4
Editor who approved publication: Professor Deyun Wang
Yunan Lin, Qiang Li, Jinlu Liu, Ruimin Yang, Jingchen Liu
Department of Anesthesiology, The First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi, People’s Republic of China
Background: This study aims to investigate differences between continuous epidural infusion (CEI) and programmed intermittent epidural bolus (IEB) analgesia for the Chinese parturients undergoing spontaneous delivery and to approach their safety to parturients and neonates.
Methods: Two hundred healthy American Society of Anesthesiologists class I or II, term (≥37 weeks’ gestation), nulliparous women who requested analgesia for labor were recruited. Epidural analgesia was initiated with a solution of 0.15% ropivacaine 10 mL and maintained with 0.1% ropivacaine mixed with sufentanil 0.3 µg/mL by CEI at a rate of 5 mL/h combined with a patient-controlled epidural analgesia (PCEA) bolus of 5 mL of ropivacaine sufentanil mixture or IEB of 5 mL of ropivacaine sufentanil mixture combined with a PCEA bolus of 5 mL of ropivacaine sufentanil mixture. The lockout interval was 20 minutes in each arm between the CEI and the IEB group. After 20 minutes of first dosage, visual analog scale (VAS) score was obtained every 60 minutes. The maternal and fetal outcome and total consumption of analgesic solution were compared.
Results: There was no difference in demographic characteristics, duration of first and second stages, delivery methods, sensory block, fetal Apgar scores, and the maternal outcomes between the CEI and IEB groups. There was a significant difference in VAS scores and epidural ropivacaine total consumption between the two groups (IEB vs CEI: 51.27±9.61 vs 70.44±12.78 mg, P<0.01).
Conclusion: The use of programmed IEB mixed with PCEA improved labor analgesia compared to CEI mixed with PCEA, which could act as maintenance mode for epidural labor analgesia.
Keywords: intermittent epidural bolus, continuous epidural infusion, labor analgesia, patient-controlled epidural analgesia
This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License.
By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.