Back to Journals » Clinical Ophthalmology » Volume 7

Comparative analysis of corneal morphological changes after transversal and torsional phacoemulsification through 2.2 mm corneal incision

Authors Assaf A, Roshdy MM

Received 10 October 2012

Accepted for publication 5 November 2012

Published 8 January 2013 Volume 2013:7 Pages 55—61

DOI https://doi.org/10.2147/OPTH.S39019

Checked for plagiarism Yes

Review by Single-blind

Peer reviewer comments 2

Ahmed Assaf, Maged Maher Roshdy

Ophthalmology Department, Ain Shams University, Cairo, Egypt

Purpose: This paper compares and evaluates the corneal morphological changes occurring after cataract surgery through a 2.2 mm corneal incision. We use two platforms for comparison and evaluation, transversal and torsional phacoemulsification.
Patients and methods: This study includes 139 consecutive cataractous eyes (nuclear color 2–4, according to the Lens Opacities Classification System III [LOCSIII]) of 82 patients undergoing cataract surgery through a 2.2 mm corneal incision. Two different phacoemulsification platforms were used and assigned randomly: we used the WhiteStar Signature® system with the Ellips™ FX transversal continuous ultrasound (US) mode for group I (mean age: 65.33 ± 6.97 years), and we used the Infiniti® system with the OZil® Intelligent Phaco (IP) torsional US mode for group II (mean age: 64.02 ± 7.55 years). The corneal endothelium and pachymetry were evaluated preoperatively and at 1 month postoperatively. Incision size changes were also evaluated.
Results: All surgeries were uneventful. Before intraocular lens implantation, the mean incision size was 2.24 ± 0.06 mm in both groups (P = 0.75). In terms of corneal endothelial cell density, neither preoperative (I vs II: 2304.1 ± 122.5 cell/mm2 vs 2315.6 ± 83.1 cell/mm2, P = 0.80) nor postoperative (I vs II: 2264.1 ± 124.3 cell/mm2 vs 2270.3 ± 89.9 cell/mm2, P = 0.98) differences between the groups were statistically significant. The mean endothelial cell density loss was 1.7% ± 1.6% and 2.0% ± 1.4% in groups I and II, respectively. Furthermore, no significant differences between groups I and II were found preoperatively (P = 0.40) and postoperatively (P = 0.68) in central pachymetry. With surgery, the mean increase in central pachymetry was 28.1 ± 23.6 µm and 24.0 ± 24.0 µm in groups I and II, respectively (P = 0.1).
Conclusion: Ellips™ FX transversal and OZil® IP torsional phacoemulsification modes are safe for performing cataract surgery, inducing minimal corneal thickness and endothelial changes.

Keywords: cornea, endothelium, transversal phacoemulsification, torsional phacoemulsification, Ellips™ FX, OZil® IP

Creative Commons License This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.

Download Article [PDF]  View Full Text [HTML][Machine readable]

 

Other article by this author:

Readers of this article also read:

Early enteral and parenteral nutritional support after hepatectomy in patients with hepatic carcinoma: a systematic review and meta-analysis

Gao LB, Tian H, Wang XG, Yu XF, Guan Y, Chen ML, Zhang J

OncoTargets and Therapy 2015, 8:623-631

Published Date: 10 March 2015

Isolated posterior uveal effusion: expanding the spectrum of the uveal effusion syndrome

Pautler SE, Browning DJ

Clinical Ophthalmology 2015, 9:43-49

Published Date: 30 December 2014

Clinical experiences in fungal keratitis caused by Acremonium

Kim SJ, Cho YW, Seo SW, Kim SJ, Yoo JM

Clinical Ophthalmology 2014, 8:283-287

Published Date: 23 January 2014

Ocular findings in two siblings with Joubert syndrome

Makino S, Tampo H

Clinical Ophthalmology 2014, 8:229-233

Published Date: 15 January 2014

Comparative visual performance with monofocal and multifocal intraocular lenses

Gundersen KG, Potvin R

Clinical Ophthalmology 2013, 7:1979-1985

Published Date: 7 October 2013

BAK additive influence on results

Shah RD, Lemon TI, Yarrow-Jenkins A

Clinical Ophthalmology 2013, 7:1081-1082

Published Date: 6 June 2013

Navigated macular laser decreases retreatment rate for diabetic macular edema: a comparison with conventional macular laser

Neubauer AS, Langer J, Liegl R, Haritoglou C, Wolf A, Kozak I, Seidensticker F, Ulbig M, Freeman WR, Kampik A, Kernt M

Clinical Ophthalmology 2013, 7:121-128

Published Date: 16 January 2013

A characteristic optic disc appearance associated with myopia in subjects with Graves' ophthalmopathy and in subjects with primary open-angle glaucoma

Yamazaki S, Inoue R, Tsuboi T, Kozaki A, Inoue T, Inoue T, Inoue Y

Clinical Ophthalmology 2013, 7:47-53

Published Date: 7 January 2013

Cognitive neuroscience of delusions in aging

Anna EM Holt, Martin L Albert

Neuropsychiatric Disease and Treatment 2006, 2:181-189

Published Date: 15 June 2006