Aberrant positioning of a central venous dialysis catheter to reveal a left-sided partial anomalous pulmonary venous connection

Authors Chintu MR, Chinnappa S, Bhandari S

Published 10 October 2008 Volume 2008:4(5) Pages 1141—1143

DOI https://doi.org/10.2147/VHRM.S2099



Manohar R Chintu, Shammikumar Chinnappa, Sunil Bhandari

Department of Nephrology, Hull and East Yorkshire Hospitals NHS Trust, Kingston upon Hull, United Kingdom

Abstract: We describe the identification of a rare, left-sided, partial anomalous pulmonary venous connection during routine central venous catheterization. To our knowledge, this is the first report in the literature to describe this anomaly in a hemodialysis patient. A young man had anomalous connection of the veins draining the upper lobe of the left lung and left innominate vein. Our case demonstrates the importance of routine fluoroscopy during insertion of central venous catheters to detect these anomalies and minimize complications.

Keywords: hemodialysis, central venous catheters, fluoroscopy, anomaly, veins

Creative Commons License © 2008 The Author(s). This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.