Back to Journals » Open Access Journal of Sports Medicine » Volume 3

Running a marathon from -45°C to +55°C in a climate chamber: a case study

Authors Kälin, Knechtle B , Rüst CA, Mydlak, Rosemann T 

Received 7 August 2012

Accepted for publication 3 September 2012

Published 25 October 2012 Volume 2012:3 Pages 131—145

DOI https://doi.org/10.2147/OAJSM.S36808

Checked for plagiarism Yes

Review by Single anonymous peer review

Peer reviewer comments 3



Kaspar Kälin,1 Beat Knechtle,1,2 Christoph Alexander Rüst,1 Karsten Mydlak,3 Thomas Rosemann1

1Institute of General Practice and Health Services Research, University of Zurich, Zurich; 2Gesundheitszentrum St Gallen, St Gallen, Switzerland; 3Gemeinschaftslabor Cottbus, Medizinisches Versorgungszentrum für Labormedizin, Mikrobiologie und Infektionsepidemiologie, Cottbus, Germany

Background: We describe a runner who completed a self-paced marathon (42.195 km) in a climate chamber with a temperature difference of 100°C, starting at an ambient temperature (Tambient) of −45°C and finishing at an Tambient of +55°C.
Methods: Tambient was set at −45°C at the start, and was steadily increased at a rate of 1°C at 4.5-minute intervals to +55°C. Before the start, after every 10.5 km, and at the end of the marathon, body mass, urine, and sweat production were measured and samples of venous blood and urine were collected. The runner’s temperature was recorded every 10 seconds at four sites, ie, the rectum for body core temperature (Tcore), and at the forehead, right wrist, and right ankle for surface temperatures (Tskin).
Results: The subject took 6.5 hours to complete the marathon, during which Tcore varied by 0.9°C (start 37.5°C, peak 38.4°C). The largest difference (Δ) of Tskin was recorded at the ankle (Δ16°C). The calculated amount of sweat produced increased by 888% from baseline. In the blood samples, myoglobin (+250%) showed the highest change. Of the pituitary hormones, somatotropic hormone (+391%) and prolactin (+221%) increased the most. Regarding fluid regulation hormones, renin (+1145%) and aldosterone (+313%) showed the greatest increase.
Conclusion: These results show that running a marathon in a climate chamber with a total ΔTambient of 100°C is possible, and that the Tambient to Tcore relationship is maintained. These results may offer insight into regulatory mechanisms to avoid hypothermia and hyperthermia. The same study is to be performed using more subjects with the same characteristics to validate the present findings.

Keywords: endocrine regulation, thermoregulation, skin temperature, ambient temperature, sweat production

Creative Commons License © 2012 The Author(s). This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.