Back to Journals » Clinical, Cosmetic and Investigational Dentistry » Volume 13

Influence of Ceramic and Substrate Types on the Microleakage of Aged Porcelain Laminate Veneers

Authors Alnakib Y, Alsaady A

Received 9 September 2020

Accepted for publication 29 January 2021

Published 11 March 2021 Volume 2021:13 Pages 67—76

DOI https://doi.org/10.2147/CCIDE.S280280

Checked for plagiarism Yes

Review by Single anonymous peer review

Peer reviewer comments 3

Editor who approved publication: Professor Christopher E. Okunseri


Yasir Alnakib,1 Ammar Alsaady2

1Department of conservative Dentistry, Faculty of Dentistry, University of Al-Ameed, Karbala, Iraq; 2Department of Conservative Dentistry, College of Dentistry, Mustansiriya University, Baghdad, Iraq

Correspondence: Yasir Alnakib 164/42 Almokhayam District, Karbala, 56001, Iraq
Tel +9647702784555
Email [email protected]

Objective: To evaluate the effects of the type of ceramic, and the influence of the type of cervical substrate on the microleakage of aged Porcelain laminate veneers (PLVs).
Materials and Methods: A total of 48 sound human maxillary premolars were divided randomly into two groups (n=24), Group A: lithium disilicate PLVs; Group B: zirconia reinforced lithium silicate PLVs. The groups were further subdivided into four subgroups (n=12): (A1, B1): finishing line placed in Class V composite filling; (A2, B2): finishing line placed in sound enamel. In subgroups A1 and B1 standardized Class V cavities were prepared and restored with nanocomposite. Standardized PLVs tooth preparation was done for the specimens in all subgroups. Cementation of PLVs was done with a light cured resin cement and specimens were stored in distilled water for 2 weeks. Mechanical load cycling (45,000 cycle, 49 N at 2.5 Hz) and thermocycling procedure (500 cycles, 5– 55°C) were done. A microleakage test was done with dye penetration (2% methylene blue) and the microleakage percentage was recorded and calculated using a stereomicroscope and ImageJ program.
Results: Means of microleakage percentage of the subgroups were: A1 (6.6075%), A2 (4.6058%), B1 (7.3158%), and B2 (6.105%), Two-way ANOVA showed a significant effect of ceramic type and cervical composite substrate. According to samples t-test, subgroup A2 was significantly lower than A1 and B2, while subgroup B2 was significantly lower than B1. A P-value≤ 0.05 was considered as statistically significant.
Conclusion: The type of ceramic and the type of substrate both affects PLV microleakage. Lithium disilicate PLVs had significantly lower microleakage compared to zirconia reinforced lithium silicate PLVs. Teeth with cervical composite substrate had a significantly higher microleakage compared to teeth with enamel substrate.

Keywords: dental leakage, dental restoration, dental veneers, VITA Suprinity, IPS e.max CAD

Creative Commons License This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.

Download Article [PDF]  View Full Text [HTML][Machine readable]