Back to Journals » Clinical Ophthalmology » Volume 6

Corneal topographic changes following trans-conjunctival 20 gauge sutureless vitrectomy (TC20V)

Authors Mohamed AAA, Abdrabbo

Received 7 January 2012

Accepted for publication 20 February 2012

Published 24 April 2012 Volume 2012:6 Pages 565—569

DOI https://doi.org/10.2147/OPTH.S29758

Review by Single anonymous peer review

Peer reviewer comments 3



Ahmed Abdel Alim Mohamed1, Mohamed Abdrabbo2
1Faculty of Medicine, Ophthalmology Department, Ain Shames University, Cairo, Egypt; 2Faculty of Medicine, Ophthalmology Department, Benha University, Benha, Egypt

Purpose: To assess the occurrence and magnitude of corneal topographic changes in phakic eyes undergoing Transconjuctival Cannulated 20 gauge Vitrectomy (TC20V) without scleral buckling or silicone oil tamponade.
Setting: Prospective randomized controlled study done at Egyptian Eye Academy.
Methods: Forty eyes of 40 patients underwent TC20V for a variety of vitreo-retinal conditions over a 1 year follow-up period. Corneal keratometric readings were obtained using Oculus Pentacam before surgery, 1 week after, and 1 month after surgery; neither scleral buckling nor silicone oil tamponade were used in order to not affect the final corneal changes. Cases with postoperative hypotony were excluded.
Results: The mean preoperative K1 (vertical keratometry) was 44.87 ± 3.55, the mean preoperative K2 (horizontal keratometry) was 44.57 ± 3.68; the mean postoperative K1 after 1 week was 45.1 ± 6.82 while the mean postoperative K2 after 1 week was 45.7 ± 3.97. Using paired t-test analysis, the P-value of the K1 change was 0.01 and P-value of the K2 change was 0.02. Both indicate minimally significant differences. One month postoperative the mean K1 was 45.2 ± 2.53 and the mean K2 was 45.1 ± 1.56 and P-values of both K1 and K2 changes after 1 month were >0.05, which indicates insignificant changes.
Conclusions: The results showed that minimal corneal topographic changes were encountered with the use of TC20V owing to the tunnel configuration of the wound, and these changes also decrease within the first month.

Keywords: TC20V, corneal topography, wound leakage, hypotony

 

Creative Commons License © 2012 The Author(s). This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.