Back to Journals » Clinical Ophthalmology » Volume 6

Comparison of ocular-surface disease index questionnaire, tearfilm break-up time, and Schirmer tests for the evaluation of the tearfilm in computer users with and without dry-eye symptomatology

Authors Ünlü C, Guney E, Sezgin Akçay BI, Akcali G, Erdogan G, Bayramlar H

Received 4 May 2012

Accepted for publication 14 June 2012

Published 10 August 2012 Volume 2012:6 Pages 1303—1306

DOI https://doi.org/10.2147/OPTH.S33588

Checked for plagiarism Yes

Review by Single anonymous peer review

Peer reviewer comments 2



Cihan Ünlü,1 Esra Güney,1 Betül İlkay Sezgin Akçay,1 Gülünay Akçalı,1 Gürkan Erdoğan,1 Hüseyin Bayramlar2

1Ümraniye Training and Research Hospital, 2Medeniyet University Göztepe Training and Research Hospital, İstanbul, Turkey

Objective: To compare the diagnostic values of the Schirmer’s and tearfilm breakup time (TBUT) tests and the Ocular Surface Disease Index (OSDI) in dry-eye syndrome.
Subjects and methods: Thirty-five employees of Ümraniye Training and Research Hospital who used computers in their daily work participated in this prospective study. All participants completed the OSDI. Following routine ophthalmologic examination, the TBUT and Schirmer’s test were undertaken and outcomes were compared.
Results: The mean age was 29.09 ± 6.73 (range 20–46) years. Mean OSDI questionnaire, TBUT, and Schirmer’s test scores were detected as 37.12 ± 19.05 (range 4–75), 11.37 ± 3.69 seconds (range 4–18 seconds), and 25.80 ± 8.43 mm (range 6–35 mm), respectively. There was a significant inverse correlation between the OSDI and TBUT scores (r = −0.385, P = 0.022). No significant correlation existed between the OSDI and Schirmer’s test scores.
Conclusion: Dry eye is a common problem among computer users. The OSDI questionnaire, used together with the TBUT, is easily performed and may be of benefit in supporting the diagnosis of dry-eye syndrome.

Keywords: computer use, dry eye, ocular-surface disease

Creative Commons License © 2012 The Author(s). This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.