Back to Journals » Clinical Ophthalmology » Volume 12

The short-term effect of acupuncture on different ocular blood flow parameters in patients with primary open-angle glaucoma: a randomized, clinical study

Authors Leszczynska A, Ramm L, Spoerl E, Pillunat LE, Terai N

Received 7 April 2018

Accepted for publication 6 June 2018

Published 19 July 2018 Volume 2018:12 Pages 1285—1291

DOI https://doi.org/10.2147/OPTH.S170396

Checked for plagiarism Yes

Review by Single-blind

Peer reviewers approved by Dr Justinn Cochran

Peer reviewer comments 3

Editor who approved publication: Dr Scott Fraser


Anna Leszczynska,* Lisa Ramm,* Eberhard Spoerl, Lutz E Pillunat, Naim Terai

Department of Ophthalmology, University Hospital Dresden, Dresden, Germany

*These authors contributed equally to this work

Introduction: To investigate the effect of acupuncture on different ocular blood flow (OBF) parameters in patients with primary open-angle glaucoma (POAG).
Patients and methods: In a prospective, randomized study, 56 POAG patients were randomly assigned either to an eye-specific acupuncture (group I, n=28) or to an eye-unspecific acupuncture treatment (group II, n=28). Blood flow parameters were measured before and 10 minutes after treatment. Parapapillary retinal blood flow was determined by the Heidelberg retina flowmeter. Retinal vessel diameters were measured by the dynamic vessel analyzer. Pulsatile ocular blood flow, ocular pulse amplitude, and IOP were investigated by the Langham OBF system. Systemic blood pressure was obtained additionally.
Results: Pulsatile ocular blood flow increased significantly after the eye-specific acupuncture treatment from 5.6±4.3 to 6.7±4.9 µL/min (P=0.014). There was no significant change in parapapillary retinal blood flow, retinal vessel diameter, systemic blood pressure, or IOP after treatment in neither of the two groups.
Conclusion: An eye-specific acupuncture treatment may affect OBF in POAG patients.

Keywords: acupuncture, glaucoma, ocular blood flow, retinal vessel diameter, Heidelberg retina flowmeter, Langham ocular blood flow system, dynamic vessel analyzer

Creative Commons License This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.

Download Article [PDF]  View Full Text [HTML][Machine readable]