-
Research and Reports in Neonatology
-
About Dovepress
Open access peer-reviewed scientific and medical journals.
-
Open Access
Dove Medical Press is now a member of the Open Access Initiative
-
An Author's Guide
A guide to help authors get their paper published.
-
Advocacy
Support Open Access and Dove Press
-
Reprints
Promotional Article Monitoring - further details
-
Favored Author Program
Real benefits for authors, including fast-track processing of papers.
PETCO2 measured by a new lightweight mainstream capnometer with very low dead space volume offers accurate and reliable noninvasive estimation of PaCO2
Methodology
(684) Views (133) Full article downloads
Authors: Takahashi D, Hiroma T, Nakamura T
Published Date October 2011
Volume 2011:1 Pages 61 - 66
DOI: http://dx.doi.org/10.2147/RRN.S23987
Daijiro Takahashi, Takehiko Hiroma, Tomohiko Nakamura
Division of Neonatology, Nagano Children’s Hospital, Nagano, Japan
Objective: Although capnometers are widely used in adult and pediatric intensive care units, they are not widely used in neonatal intensive care units due to issues such as the weight of sensors, dead space, and leakage from tracheal intubation tubes. These authors developed a light and low dead space airway adaptor of end-tidal carbon dioxide pressure (PETCO2) and evaluated the correlations between PETCO2 and partial CO2 pressure (PaCO2) in rabbits while changing tidal volume and leakage volume.
Methods: Firstly, Japanese rabbits weighing 2 kg were divided into three tidal volumes (6 mL/kg, 10 mL/kg, or 15 mL/kg), and PETCO2 and PaCO2 were measured. Secondly, the respiratory apparatus was set to a tidal volume/body weight ratio of 10 mL/kg, leakage rates were divided into seven groups, and PETCO2 and PaCO2 were measured.
Results: PETCO2 and PaCO2 were significantly correlated (r2 = 0.9099, P < 0.0001) when there was no leakage in the tracheal intubation tubes. No significant differences were observed between PaCO2 and PETCO2 (Pa-ETCO2) in the three tidal volume/body weight groups or for groups in which leakage rate was <60%, but significant deviations in Pa-ETCO2 were noted in groups with leakage rate 60%.
Conclusion: There was a strong correlation between PETCO2 and PaCO2 when tidal volume/body weight ratio was 6–15 mL/kg with leakage rate <60%. Lightweight mainstream capnometer with a low amount of dead space airway adaptor might be useful in very low birth weight infants with small tidal volume.
Keywords: capnography, mainstream, neonate
Other articles by Professor Tomohiko Nakamura
Nonpathogenic bacterial flora and immunoglobulin A in the oral cavity inhibit colonization of methicillin-resistant Staphylococcus aureus in very low birth weight infants
Readers of this article also read:
Traditional open-bay versus single-family room neonatal intensive care unit: a comparison of selected nutrition outcomes
Nonpathogenic bacterial flora and immunoglobulin A in the oral cavity inhibit colonization of methicillin-resistant Staphylococcus aureus in very low birth weight infants
Primary prevention of coronary heart disease: integration of new data, evolving views, revised goals, and role of rosuvastatin in management. A comprehensive survey
Sudden cardiac death in young athletes
Twin versus singleton pregnancies: the incidence, pregnancy complications, and obstetric outcomes in a Nigerian tertiary hospital
The FiO2 is associated with the successful extubation of mechanically ventilated neonates
Kidney function and mortality post-liver transplant in the Model for End-Stage Liver Disease era
Alternative therapies for respiratory distress syndrome in preterm infants
Evaluation of factors influencing stable microbubble test results in preterm neonates at 30–33 gestational weeks
-
Call For Submissions
Submit Original Research Article, Review, Case Report, or Rapid Communication in Research and Reports in Neonatology
- Disparities in health care utilization among Latino children suffering from asthma in California
- Multidrug-resistant Acinetobacter lwoffii infection in neonatal intensive care units
- Physical growth in children with transfusion-dependent thalassemia
- Traditional open-bay versus single-family room neonatal intensive care unit: a comparison of selected nutrition outcomes




