Back to Journals » Clinical Ophthalmology » Volume 7

Use of 25% sulfur hexafluoride gas mixture may minimize short-term postoperative hypotony in sutureless 25-gauge pars plana vitrectomy surgery

Authors Barak Y, Heroman J, Schaal S

Received 8 November 2012

Accepted for publication 11 December 2012

Published 26 February 2013 Volume 2013:7 Pages 423—426

DOI https://doi.org/10.2147/OPTH.S40108

Checked for plagiarism Yes

Review by Single anonymous peer review

Peer reviewer comments 2



Yoreh Barak, James W Heroman, Shlomit Schaal

Department of Ophthalmology and Visual Sciences, University of Louisville, Louisville, KY, USA

Background: The purpose of this study was to compare postoperative intraocular pressures and percentage of vitreous cavity gas fill one day following 25-gauge pars plana vitrectomy with 20% versus 25% sulfur hexafluoride (SF6) gas fill.
Methods: This was a retrospective review of 187 consecutive cases of 25-gauge pars plana vitrectomy with complete fluid/gas exchange. The main outcome measures included percentage of gas fill of the vitreous cavity and intraocular pressure on postoperative day one.
Results: Fifty eyes underwent 25-gauge pars plana vitrectomy with 20% SF6 tamponade and 137 with 25% SF6 tamponade. On postoperative day one in the 20% SF6 group, there were five (10%) patients with hypotony (intraocular pressure ≤ 5 mmHg) and none in the 25% SF6 group. Mean intraocular pressure was 9 ± 2.5 mmHg and 16.8 ± 2.4 mmHg for the 20% SF6 and 25% SF6 groups, respectively (P < 0.01). None of the patients had postoperative intraocular pressure > 23 mmHg. Mean vitreous cavity gas fill on postoperative day one was 70.7% ± 10% in the 20% SF6 group and 89.5% ± 2.2% in the 25% SF6 group (P < 0.01). There was no difference in the number of phakic patients needing cataract surgery between the groups.
Conclusion: A slightly expansile concentration of 25% SF6 gas can be safely and beneficially used in 25-gauge vitrectomy surgery to increase the amount of gas fill in the vitreous cavity and prevent postoperative hypotony.

Keywords: hypotony, 25-gauge pars plana vitrectomy, sulfur hexafluoride

Creative Commons License © 2013 The Author(s). This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.