Salivary glucose concentration exhibits threshold kinetics in normal-weight, overweight, and obese children

Authors Hartman M, Goodson M, Barake R, Alsmadi O, Al-Mutawa S, Ariga J, Soparkar P, Behbehani J, Behbehani K, Welty FK

Received 15 August 2014

Accepted for publication 12 September 2014

Published 17 December 2014 Volume 2015:8 Pages 9—15

DOI https://doi.org/10.2147/DMSO.S72744

Checked for plagiarism Yes

Review by Single-blind

Peer reviewer comments 3

Editor who approved publication: Professor Ming-Hui Zou


Mor-Li Hartman,1 J Max Goodson,1 Roula Barake,2 Osama Alsmadi,3 Sabiha Al-Mutawa,4 Jitendra Ariga,4 Pramod Soparkar,1 Jawad Behbehani,5 Kazem Behbehani,6 Francine Welty7

1Department of Applied Oral Sciences, The Forsyth Institute, Cambridge, MA, USA; 2Department of Nutrition, The Dasman Diabetes Institute, Dasman, Kuwait; 3Genome Center, The Dasman Diabetes Institute, Dasman, Kuwait; 4Ministry of Health, Kuwait City, Kuwait; 5Faculty of Dentistry, Kuwait University, Kuwait City, Kuwait; 6The Dasman Diabetes Institute, Dasman, Kuwait; 7Division of Cardiology, Beth Israel Deaconess Medical Center, Boston, MA, USA


Background: Metabolic syndrome in childhood predicts the development of cardiovascular disease and type 2 diabetes (T2D) in adulthood. Testing for features of metabolic syndrome, such as fasting plasma glucose concentration, requires blood sampling which can be difficult in children. Here we evaluated salivary glucose concentration as a surrogate measurement for plasma glucose concentration in 11-year-old US children.
Methods: Children from Portland, Maine, and Cambridge, Massachusetts, with a mean age of 10.6±0.2 years provided 6-hour fasting samples of both blood and whole saliva. Salivary glucose levels were measured with a high-sensitivity assay (sensitivity =0.002 mg/dL). Plasma glucose levels were determined by a commercial clinical laboratory. Blood pressure, salivary flow rate, height, and weight were also measured.
Results: Of the 65 children enrolled, there were two underweight children (3.1%), 30 normal-weight children (46.2%), 12 overweight children (18.4%), and 21 obese children (32.3%). The mean overall glucose concentrations were 0.11±0.02 mg/dL in saliva and 86.3±0.8 mg/dL in plasma, and these did not differ significantly by body–weight groups. By regression analysis, the plasma concentration equaled 13.5 times the saliva concentration, with a threshold level of 84.8 mg/dL. Salivary glucose values less than threshold plasma concentration were essentially zero. Diagnostic analysis indicated a positive predictive value of 50%, a negative predictive value of 90%, and a sensitivity and specificity both of approximately 75%. The salivary glucose concentration did not vary with saliva flow rate.
Conclusion: Taking into account the threshold response characteristics of the salivary glucose concentration response, these results suggest that testing salivary glucose levels may be useful as a screening assay for high fasting plasma glucose levels. The low false positive value is important to assure a low fraction of missed diagnoses.

Keywords: saliva, salivary glucose, plasma glucose, children

Creative Commons License This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.