Meta-analysis of the ocular biocompatibility of a new multipurpose lens care system

Authors Reindel W, Merchea MM, Rah MJ , Zhang L

Received 23 May 2013

Accepted for publication 20 August 2013

Published 14 October 2013 Volume 2013:7 Pages 2051—2056

DOI https://doi.org/10.2147/OPTH.S48914

Checked for plagiarism Yes

Review by Single anonymous peer review

Peer reviewer comments 4



William Reindel, Mohinder M Merchea, Marjorie J Rah, Lening Zhang

Bausch & Lomb Incorporated, Rochester, NY, USA

Background: The purpose of this paper is to evaluate the biocompatibility of a novel multipurpose solution (MPS) with a dual disinfectant system containing polyaminopropyl biguanide and polyquaternium-1 (Biotrue®) by analysis of biomicroscopy signs and adverse events in six large clinical trials.
Methods: Data from six consecutive, prospective clinical trials conducted from February 2008 to March 2010 were combined for meta-analysis. Subjects used the new MPS daily for periods of 2 weeks to 6 months. Slit-lamp signs were graded at each follow-up visit using an ordinal scale (0, one; 1, trace; 2, mild; 3, moderate; 4, severe). Analysis for biocompatibility included tracking of greater than grade 2 slit-lamp findings and number of adverse events.
Results: A total of 1,567 subjects (3,134 eyes) and 81 clinical investigators participated in the six studies, with 1,499 subjects completing the studies. Based on subject days in the studies, there were 72,904 exposures to the MPS and 7,212 biomicroscopy examinations. The completion rate for the studies was 96.3%. Per observation incidence of any finding greater than grade 2 at the follow-up visits were: corneal staining 0.08%, limbal injection 0.04%, bulbar injection 0.04%, tarsal conjunctiva abnormality 0.09%, and neovascularization 0.01%. There were no other slit-lamp signs greater than grade 2 and no statistically significant difference between hydrogels and silicone hydrogels for any finding. There were no reports of adverse events during the trials.
Conclusion: Analysis of over 72,000 daily exposures and 7,212 eye examinations showed that the novel MPS exhibited excellent biocompatibility in subjects using daily wear hydrogel or silicone hydrogel lenses.

Keywords: contact lens, solutions, disinfection, meta-analysis, silicone, hydrogel

Creative Commons License © 2013 The Author(s). This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.