Intra- and inter-rater reproducibility of the 6-minute walk test and the 30-second sit-to-stand test in patients with severe and very severe COPD

Authors Hansen H, Beyer N, Frølich A, Godtfredsen N, Bieler T

Received 15 May 2018

Accepted for publication 3 September 2018

Published 18 October 2018 Volume 2018:13 Pages 3447—3457

DOI https://doi.org/10.2147/COPD.S174248

Checked for plagiarism Yes

Review by Single-blind

Peer reviewers approved by Dr Colin Mak

Peer reviewer comments 3

Editor who approved publication: Dr Richard Russell


Henrik Hansen,1 Nina Beyer,2 Anne Frølich,1 Nina Godtfredsen,2,3 Theresa Bieler4

1Research Unit of Chronic Diseases and Telemedicine – Center for Clinical Research and Prevention, Bispebjerg and Frederiksberg University Hospital, Copenhagen, Denmark; 2Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark; 3Department of Respiratory Medicine, Hvidovre University Hospital, Hvidovre, Denmark; 4Department of Physical and Occupational Therapy, Bispebjerg and Frederiksberg Hospital, University of Copenhagen, Copenhagen, Denmark

Background: In patients with COPD, the 6-minute walk test (6MWT) and the 30-second sit-to-stand test (30sec-STS) are widely used as clinical outcome measures of walking capacity, lower limb muscle strength, and functional ability. Due to a documented learning effect, at least two trials are recommended for assessment. The aim of our study was to investigate the intra- and inter-rater reliability and agreement of the two tests in patients with severe and very severe COPD (FEV1 <50%).
Patients and methods: Fifty patients (22 females; mean [SD]: age 67 [9] years, FEV1 predicted 32 [9]%) were assessed with the 6MWT and the 30sec-STS twice by the same assessor on test-day 1 (T1) and by another assessor 7–10 days later on test-day 2 (T2).
Results: The 6MWT intra- and inter-rater reliability (intraclass correlation coefficient, ICC1.1) was 0.98 (lower limit 95% CI: 0.94) and 0.96 (lower limit 95% CI: 0.94), respectively, and agreement (standard error of the measurement, SEM) was 14.8 and 20.5 m, respectively. The 30sec-STS intra- and inter-rater reliability and agreement results were, respectively, ICC1.1 0.94 (lower limit 95% CI: 0.90) and 0.92 (lower limit 95% CI: 0.86), with SEM of 0.97 and 1.14 repetitions. There was no difference (95% CI: -5.3; 8.1) between the 6MWT distances on T1, while the mean walking distance improved 7.9 m (0.0 m; 15.8 m) from T1 to T2. Improvement on the same test date was less likely (OR: 3.6 [95% CI: 1.1; 11.8], Fisher’s exact test, P=0.047) in patients who walked less than 350 m in the 6MWT. We found no clinically relevant learning effect in the 30sec-STS.
Conclusion: In patients with severe and very severe COPD the 6MWT and the 30sec-STS showed excellent intra- and inter-rater reliability and acceptable agreement. No learning effect was documented for the tests when performed on the same day. Our data suggest that in clinical practice using different assessors is acceptable, and that a single test trial may be sufficient to assess patients with severe and very severe COPD.

Keywords: COPD, exercise test, outcome assessment, lower extremity, reproducibility of results

Creative Commons License This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.