Back to Journals » Diabetes, Metabolic Syndrome and Obesity » Volume 5

Glucose estimation in the salivary secretion of diabetes mellitus patients

Authors Panda A, Ramesh, Oza

Received 22 March 2012

Accepted for publication 20 April 2012

Published 12 July 2012 Volume 2012:5 Pages 149—154

DOI https://doi.org/10.2147/DMSO.S32112

Review by Single anonymous peer review

Peer reviewer comments 1



Abikshyeet Panda,1 Ramesh Venkatapathy,2 Nirima Oza2

1Department of Oral Pathology, Kalinga Institute of Dental Sciences, Kalinga Institute of Industrial Technology University, Bhubaneswar, Odisha, 2Department of Oral Pathology and Microbiology, Mahatma Gandhi Post Graduate Institute of Dental Sciences, Puducherry, India

Aim: Saliva is one of the most abundant secretions in the human body and its collection is easy and noninvasive. The aim of this study was to find a medium that can be used to diagnose and monitor diabetes. In this, saliva could play a major role. To substantiate the role of saliva as a diagnostic tool, we compared saliva samples with blood glucose and glycated hemoglobin (HbA1c) in healthy and diabetic subjects.
Materials and methods: Included in the study were 106 patients, newly diagnosed with type 2 diabetes mellitus and 15 healthy control subjects. The patients and control subjects were asked to come to the clinic in the morning, after an 8-hour fast. At that time, 5 mL of venous blood was collected, 2 mL of which was collected in an ethylenediaminetetraacetic acid (EDTA)-containing blood collection tube and sent for HbA1c estimation. Unstimulated saliva was collected from both groups as well. The saliva and sera from the blood samples were subjected to glucose estimation.
Results: The correlation coefficient between serum glucose and salivary glucose in the control group was calculated and the r value was found to be 0.5216, which was statistically significant
(P < 0.05). The correlation coefficient between serum glucose and salivary glucose in the patient group was also calculated and the r value was found to be 0.7686, which was highly significant
(P < 0.01). Finally, the correlation coefficient between HbA1c level and salivary glucose in the patient group was calculated and the r value was found to be 0.5662, which was also highly significant
(P < 0.01).

Keywords: saliva, salivary glucose, serum glucose, insulin, hyperglycemia

Creative Commons License © 2012 The Author(s). This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.