Back to Journals » International Journal of Chronic Obstructive Pulmonary Disease » Volume 10 » Issue 1

Exhaled volatile organic compounds discriminate patients with chronic obstructive pulmonary disease from healthy subjects

Authors Besa V, Teschler H, Kurth I, Khan AM, Zarogoulidis P, Baumbach JI, Sommerwerck U, Freitag L, Darwiche K

Received 22 October 2014

Accepted for publication 10 January 2015

Published 23 February 2015 Volume 2015:10(1) Pages 399—406

DOI https://doi.org/10.2147/COPD.S76212

Checked for plagiarism Yes

Review by Single anonymous peer review

Peer reviewer comments 5

Editor who approved publication: Dr Richard Russell



Vasiliki Besa,1 Helmut Teschler,2 Isabella Kurth,1 Amir Maqbul Khan,3 Paul Zarogoulidis,4 Joerg Ingo Baumbach,5 Urte Sommerwerck,2 Lutz Freitag,1 Kaid Darwiche1

1Department of Interventional Pneumology, Ruhrlandklinik, West German Lung Center, University Hospital, University Duisburg-Essen, Essen, Germany; 2Department of Pneumology, Ruhrlandklinik, University Hospital Essen, University of Essen-Duisburg, Essen, Germany; 3Division of Thoracic Surgery, Toronto General Hospital, University Health Network, University of Toronto, Toronto, ON, Canada; 4Oncology Unit, Pulmonary Department, “G Papanikolaou” General Hospital, Aristotle University of Thessaloniki, Greece; 5Faculty of Applied Chemistry, Reutlingen University, Reutlingen, Germany

Abstract: Chronic obstructive pulmonary disease (COPD) is a chronic airway inflammatory disease characterized by incompletely reversible airway obstruction. This clinically heterogeneous group of patients is characterized by different phenotypes. Spirometry and clinical parameters, such as severity of dyspnea and exacerbation frequency, are used to diagnose and assess the severity of COPD. The purpose of this study was to investigate whether volatile organic compounds (VOCs) could be detected in the exhaled breath of patients with COPD and whether these VOCs could distinguish COPD patients from healthy subjects. Moreover, we aimed to investigate whether VOCs could be used as biomarkers for classifying patients into different subgroups of the disease. Ion mobility spectrometry was used to detect VOCs in the exhaled breath of COPD patients. One hundred and thirty-seven peaks were found to have a statistically significant difference between the COPD group and the combined healthy smokers and nonsmoker group. Six of these VOCs were found to correctly discriminate COPD patients from healthy controls with an accuracy of 70%. Only 15 peaks were found to be statistically different between healthy smokers and healthy nonsmokers. Furthermore, by determining the cutoff levels for each VOC peak, it was possible to classify the COPD patients into breathprint subgroups. Forced expiratory volume in 1 second, body mass index, and C-reactive protein seem to play a role in the discrepancies observed in the different breathprint subgroups.

Keywords: breath analysis, COPD, ion mobility spectrometry, volatile organic compounds


Introduction

Chronic obstructive pulmonary disease (COPD) is a common preventable and treatable disease worldwide and is one of the leading causes of morbidity and mortality. COPD is characterized by persistent limitation of airflow due to an abnormal inflammatory response of the lungs to the inhalation of noxious particles and gases and is mainly caused by cigarette smoking. The limitation of airflow is best measured by spirometry, which is widely available and reproducible.1 However, the lung function parameters obtained from spirometry do not always yield assessments of airway inflammation and severity of disease. Dyspnea and rate of exacerbations are essential for investigating the underlying mechanisms of the disease and for assessing severity of the disease and the response to the therapy.2 Furthermore, some subjects are not compliant enough to provide a good spirometry test; therefore, there is a need for additional methods that provide more information about the disease than airway limitation.3

Noninvasive methods, including the analysis of exhaled breath, have been studied in the past decades for their applicability in the assessment of airway inflammation and as possible diagnostic tools in several inflammatory lung diseases. A large number of biomarkers in breath have been investigated as possible indicators of inflammation, to diagnose and monitor the disease as well as to evaluate the response to treatment. Exhaled breath is known to contain many volatile organic compounds (VOCs) at very low concentrations (nanomolar [109] or picomolar [10−12]).4,5 These VOCs may be products of various inflammatory and metabolic processes, either physiological or disease-related, that take place in the airways and other parts of the human body, or products of the oxidative stress that occurs in diseases such as asthma and COPD.6,7 Therefore, the detection of VOCs in the exhaled breath is an attractive method to investigate possible biomarkers for diagnosing, monitoring, and assessing the oxidative stress of various lung diseases.5,8 Previous studies have shown that a profile of VOCs could be used as a biomarker in lung cancer,9,10 asthma,11,12 sarcoidosis,13 tuberculosis,14 and obstructive sleep apnea syndrome.15,16 Profiles of exhaled VOCs provide fingerprints of diseases, the so-called “breathprints,” allowing for discriminating between patients and healthy subjects, without the need for chemical identification of the underlying substances.

Nowadays, many techniques are available to collect and analyze VOCs, such as the electronic nose (eNose), gas chromatography (GC) followed by either mass spectrometry (GCMS) or flame ionization detection (GC-FID), proton transfer reaction mass spectrometry (PTR-MS), selected ion flow tube mass spectrometry (SIFT-MS), laser spectroscopy, colorimetric sensor array and gold nanoparticle sensors (GNPs).17 Exhaled VOCs detected by gas chromatography–mass spectrometry have been shown to discriminate patients with asthma or COPD from healthy subjects;18,19 as well as patients with COPD from patients with asthma or lung cancer with the use of the electronic nose.11,20 Ion mobility spectrometry (IMS) has been used in several studies for detecting VOCs in patients with several lung diseases.13,21,22 IMS is a new, on-site method, rapid and easy to use for detecting and separating VOCs according to their detection time, drift time, and their concentration in the exhaled breath. Moreover, IMS enables the visualization of VOCs in a three-dimensional topography, the so-called IMS chromatograph.23,24

The purpose of this study was to detect in the exhaled breath of patients with COPD VOCs that could be used as biomarkers in the diagnosis of the disease. Furthermore, we aimed to detect VOCs that could be used as possible biomarkers for classifying patients into different subtype groups of the disease.

Methods

Study subjects

The patients included in the study were recruited from the Department of Pneumology, Ruhrlandklinik, University Hospital of Essen, Germany. Patients had an established diagnosis of COPD according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD) guidelines.1 All patients had a history of smoking (>20 pack per years) and an irreversible limitation of airflow (reversibility <12% predicted forced expiratory volume in 1 second [FEV1] and <200 mL in FEV1) after inhalation of β2-agonist. Patients were asked for comorbidities and in case of other existing respiratory and inflammatory diseases or malignancies, they were excluded from the study. All patients had no signs of acute exacerbation for at least 4 weeks prior to enrollment.

The control groups consisted of healthy smokers and nonsmokers, and all were employees of the hospital. All healthy subjects had no history of respiratory disease and underwent lung function measurements to exclude obstructive lung disease. The nonsmoking subjects had a smoking history of less than two packs per year and had stopped smoking for at least 1 year. The study was approved by the ethics committee of the University of Essen and all subjects provided written informed consent.

Study design

All VOC measurements were performed with the same ion mobility spectrometer device, in the same room and at the same daytime to avoid biased variations. The study participants were requested to refrain from eating, drinking, and smoking for 2 hours prior to the measurement. All subjects underwent a medical history review, a physical examination, and a collection of breath air. Repeated measurements on the same day were performed in a subgroup of the healthy subjects to assess the within-day repeatability of the measurements.

Lung function tests

The lung function tests were performed by a trained lung function technician using Zan500 Body (nSpire Health, Oberthulba, Germany) according to the American Thoracic Society/European Respiratory Society recommendations.25

Collection of exhaled breath

All subjects were requested to exhale through a mouthpiece connected via a Teflon tube with the spectrometer. In each case, end-tidal breath, controlled by a flow sensor, was collected in a sample loop of 10 mL in volume. The sample air was collected and transferred to a multicapillary column for a first chromatographic separation. Using the software VOCan 1.3 (B&S Analytik, Dortmund, Germany), the dead volume was adjusted and fixed to 500 mL. The expiration was controlled by an ultrasound CO2 sensor element.

Analysis of exhaled breath

The IMS coupled to the multicapillary column (MCC/IMS) was a BioScout (B&S Analytik), consisting of the MCC/IMS and a SpiroScout (GanhornMedizin Electronic, Niederlauer, Germany) as a sample inlet unit. The major parameters of this setup are summarized elsewhere.24,26 In this spectrometer, a 550 MBq63 Ni β-radiation source was applied for the ionization of the carrier gas (air). The spectrometer was connected to a polar, multicapillary column (MCC, type OV-5; Multichrom Ltd, Novosibirsk, Russia) that was used as the preseparation unit. In this MCC, the analytes of exhaled breath were sent through 1,000 parallel capillaries, each with an inner diameter of 40 μm and a film thickness of 200 nm. The total diameter of the separation column was 3 mm. The relevant MCC parameters are listed in Table 1.

Table 1 Characteristics of ion mobility spectrometer
Abbreviation: MCC, multicapillary column.

Data mining and evaluation

The peaks were characterized using the software Visual Now (B&S Analytik), which is described elsewhere.27,28 All peaks found are characterized by their positions with respect to drift time (corresponding 1/K0 value), retention time, and their concentration in relation to the peak height.22,28

Statistical analysis

The statistical analysis was performed using SPSS (version 17.0). The normality of distributions was evaluated with the Kolmogorov–Smirnov test. The comparisons among groups were performed with one-way analysis of variance for normally distributed data and with the Kruskal–Wallis test for skewed data, with appropriate post hoc tests to adjust for multiple comparisons (Bonferroni). The difference of a numerical variable between two groups was evaluated with an unpaired t-test or Mann–Whitney U-tests for normal and skewed data, respectively.

Furthermore, a classification model was constructed using twofold cross-validation. The training data were randomly split in two parts: one to develop the model and one to measure its performance.

Results

The subjects’ characteristics are summarized in Table 2. Breath analysis was performed on 45 COPD patients (aged 56.2±8.5 years), 23 healthy smokers (aged 38.7±14 years) and 28 healthy nonsmokers (aged 42.5±8.4 years). There were no significant differences in sex and body mass index (BMI) among the three groups. The COPD patients had a heavier smoking history than the healthy smokers (33±14 packs per year vs 18.6±18 packs per year).

Table 2 Patients’ characteristics
Notes: aStatistically significant difference compared to healthy smokers; bstatistically significant difference compared to healthy nonsmokers.
Abbreviations: FEV1, forced expiratory volume in 1 second; VC, vital capacity; BMI, body mass index; COPD, chronic obstructive pulmonary disease; ns, not significant; pred, predicted.

The mean FEV1 (predicted percentage) in patients with COPD was 28.3±18.9 vs 105.6±8.0 in healthy smokers and 97±14 in healthy nonsmokers. The severity of COPD was GOLD IV (n=21), GOLD III (n=16), GOLD II (n=5), and GOLD I (n=3). Patients were referred to the Department of Pneumology, University Hospital of Essen, to examine the potential for endoscopic or surgical lung volume reduction or for their addition to the lung transplant waiting list.

A total of 224 VOC peaks were identified, as characterized by drift and retention times (Figure 1). The signal intensity of the peaks was statistically evaluated with the Wilcoxon rank sum test. One hundred and thirty-seven peaks were found to have a statistically significant difference between the COPD group and the combined healthy smokers and nonsmokers group. When the healthy smokers and the healthy nonsmokers were compared with each other, only 15 peaks were found to be statistically different between the two groups (EES, EJ, FI, FL, FP, GF, P, PS 22, PS3, P1, P2, P27, P38, P4, and P40) (Supplementary information). Using 50:50 cross-validation, six peaks (PS0, PS14, PS47, P51, P52, and P2) from among the total of 137 (Figure 2) were found to correctly classify (with an accuracy of 71%, 70%, 70%, 71%, 70%, and 67%, respectively) the COPD patients from the healthy controls (smokers and nonsmokers combined).

Figure 1 The IMS chromatogram showing the 224 peaks that were detected in the exhaled breath of COPD patients.
Abbreviations: IMS, ion mobility spectrometry; COPD, chronic obstructive pulmonary disease.

Figure 2 Box-and-whisker plots of the six peaks P2, P51, P52, PS0, PS14, and PS47 that differentiated the COPD patients from the healthy subjects (healthy smokers and healthy nonsmokers).
Abbreviation: COPD, chronic obstructive pulmonary disease.

For each peak, a cutoff value in signal intensity was determined such that the COPD patients were correctly classified as COPD and the healthy controls as non-COPD, with a specificity of 100%. Using this cutoff value for each peak, we examined if the COPD patients lie above or below this cutoff value. It becomes apparent that the vast majority of the patients (41 out of 45) have at least five out of the six peaks above or below this cutoff. When their peaks were found above the cutoff, it was defined as “typical COPD breathprint.” When the peaks were found to be below (again at least five of the six peaks), patients were defined as having “no typical COPD breathprint.”

In only four patients, no more than four peaks were in accordance to classify the patients into one of these two breathprint subgroups. These four patients were excluded from further analysis, which was performed to investigate the reason for these discrepancies. These four patients seemed to have no common characteristics in their breathprints. Thus, 23 of 41 patients were classified as having a “typical COPD breathprint” and 18 as not having a “typical COPD breathprint.”

To further investigate the possible reasons for the discrepancies in the breathprints of these patients, we examined a set of clinical parameters that were likely to discriminate these two breathprint subgroups. From these parameters, the subgroup of patients with a “typical COPD breathprint” by VOC profile had statistically significant higher FEV1, BMI, and lower CRP in comparison with the subgroup without “typical COPD breathprint” by VOC profile (Table 3). For other parameters, no significant differences between the two subgroups could be found.

Table 3 Clinical parameters of COPD patients with and without “typical COPD breathprint”
Abbreviations: FEV1, forced expiratory volume in 1 second; BMI, body mass index; CRP, C-reactive protein; COPD, chronic obstructive pulmonary disease; pred, predicted.

Discussion

Using IMS, we have shown that the VOC profile of the exhaled breath of COPD patients is different from that of healthy subjects. Six VOCs were found to classify and distinguish correctly the COPD patients from healthy subjects. Further, by using cutoff levels for each of the six VOC peaks, it was possible to discriminate the COPD patients into two breathprint subgroups, patients with a “typical COPD breathprint” and patients without a “typical COPD breathprint.”

The use of noninvasive techniques for assessing airway inflammation, such as the analysis of exhaled breath, has developed rapidly since nitric oxide was described as an important biomarker in the exhaled breath of asthma patients.29 Apart from nitric oxide, a large number of biomarkers have been tested in exhaled breath with various noninvasive methods, such as induced sputum and exhaled breath condensate, to investigate, assess, and monitor airway inflammation or oxidative stress in lung diseases.30 These noninvasive diagnostic methods are very attractive for clinical settings also because they are easy to perform and safe for the patients. Furthermore, these noninvasive methods, in contrast to invasive methods, can be easily repeated and applied by patients with severe diseases.

Recent studies have also shown discrimination of COPD patients from healthy subjects using several methods for detecting VOCs in exhaled breath. Our findings are in accordance with the recent study of Basanta et al31 which discriminated COPD patients from healthy subjects with an accuracy of 69% using gas chromatography time-of-flight mass spectrometry. In a study by van Berkel et al19 using gas chromatography–mass spectrometry, six peaks were detected that classified correctly 92% of the patients with a sensitivity of 98% and a specificity of 88%. However, these two studies included a larger proportion of current smokers (31% and 76%, respectively) than was included in our study (13%). This higher proportion of smokers in these two studies could possibly explain the higher accuracy of discriminating COPD patients from healthy subjects compared to the results of our study. Phillips et al32 also showed using gas chromatography–mass spectrometry, in a large study group of 119 COPD patients and 63 healthy subjects, that VOCs can distinguish COPD patients from healthy subjects with a high accuracy of 74%. In their study, the COPD and control group were matched for age and BMI because these factors could possibly affect VOCs.32 In our study, no difference was found for BMI between the two groups, but age was statistically different between the two groups. While age is a possible factor affecting VOCs via oxidative stress, currently only few data provide support for this suggestion.3335

The study of Phillips et al32 implies that smoking status influences the correct classification of COPD patients as active smoking may be a confounding factor in the analysis of exhaled breath. Previous studies have shown that active smoking influences the VOC profile in exhaled breath.8,36,37 However, when we compared healthy smokers with healthy nonsmokers in our study, 15 peaks that were found to distinguish the two groups were not similar to the peaks that distinguished COPD patients from healthy subjects (smoking and nonsmoking combined). Consequently, it is probable that smoking did not affect our results.

Identification of the underlying substances detected in the exhaled breath was beyond the scope of this investigation. Substance identification is not strictly necessary because IMS allows for the detection of VOC profiles that are themselves useful as potential markers for detecting disease without the need for further chemical analysis. A recent study could show using the electronic nose that VOCs could identify bacterial colonization in COPD patients.38 This could be a subject for a future study using the IMS. An interesting aspect of this study was that by identifying cutoff values for each of the six peaks that discriminated COPD patients from healthy subjects, these peaks were found to be unequally distributed among COPD patients. In contrast, COPD patients could be further classified into two breathprint subgroups: those with a “typical COPD breathprint” and those without a “typical COPD breathprint.” This finding implies that there are plausible subtypes within COPD patients and that these subtypes can be identified by breath analysis. This result is in accordance with the study of Basanta et al31 which showed that VOCs in exhaled breath identified clinically relevant subgroups, eg, COPD patients with sputum eosinophilia, asymptomatic smokers, or patients with frequent exacerbations.

It is known that COPD is a complex and multidimensional disease with different pulmonary and extrapulmonary manifestations.39 Although diagnosis and monitoring of the disease are based on lung function tests, it is now known that the measurement of FEV1 alone does not express the full complexity of the disease. Various phenotypes reflect several clinical, immunological, and inflammatory mechanisms of COPD that influence the outcome of the disease and the response to treatment.33,40

To elucidate the parameters that are associated with the discrepancy in classifying COPD patients by the VOC profiles identified in our study, we analyzed further the differences in FEV1, BMI, CRP, age, serum creatinine, packs per year, pO2, and pCO2 between the two subgroups. Our finding that patients with lower FEV1 do not show a “typical COPD breathprint” may be explained by higher oxidative stress in a more severe stage of the disease. This suggestion could explain the finding that patients without “typical COPD breathprint” had lower BMI and higher CRP, indicators for systemic inflammation, which is more prominent in severe COPD. Another possible explanation could be that metabolic processes independent of inflammation influence the breathprint of patients with more severe disease in a way that they have similarities with the breathprint of healthy subjects. Further characterization of these COPD patients using other inflammatory biomarkers or clinical data is of interest and should be investigated in further studies.

Our study has certain limitations. Repeated IMS measurements were performed in healthy subjects on the same day, showing good reproducibility. However, reproducibility was not tested in COPD patients. It is suggested that sample variability and short-term effects of practice or exertion should be considered in breath analysis tests.41 Incalzi et al3 suggest that VOC patterns are reproducible in healthy subjects and patients with very severe COPD, whereas these are less reproducible in COPD patients with less severe disease. This finding may reflect hypoxemia, which characterizes these patients. As the majority of the patients measured in this study suffer from severe COPD, variability of IMS measurement might not be a confounding factor in our study. Another limitation of our study is that no information was collected regarding medication of the patients. Further studies are needed to test the possible effects of medication on exhaled breath and to test repeatability and reproducibility in COPD patients. Although identification of the underlying substances of the detected VOCs was beyond the interest of this study, this could be a subject of future studies that would probably reveal the origin of these compounds and further elucidate the pathophysiological mechanisms involved in the pathogenesis of COPD.

Conclusion

In this study, it was shown that the identification of VOCs using IMS was able to distinguish COPD patients from healthy subjects. Two subgroups of COPD patients were identified according to their VOC breathprints. Further studies with larger sample size are needed to completely characterize these subgroups, as well as to identify the underlying substances of the VOCs.

Acknowledgments

The authors thank Gabriele Kentrat (Ruhrlandklinik, Essen, Germany) for her assistance with data collection. This research has been supported by the “Deutsche Forschungsgemeinschaft” within the Collaborative Research Center (“Sonderforschungsbereich”) SFB 876.

Disclosure

Baumbach JI has shares as inventor in diverse patents and is shareholder of a company that produces ion mobility spectrometers. The other authors report no conflicts of interest in this work.


References

1.

Global Strategy for the Diagnosis, Management and Prevention of COPD. Global Initiative for Chronic Obstructive Lung Disease (COPD) Revised 2014 [Internet]. Available from: http://www.goldcopd.org/

2.

Rabe KF, Hurd S, Anzueto A, et al. Global strategy for the diagnosis, management, and prevention of chronic obstructive pulmonary disease: GOLD executive summary. Am J Respir Crit Care Med. 2007;176(6):532–555.

3.

Incalzi RA, Scarlata S, Pennazza G, Santonico M, Pedone C. Chronic obstructive pulmonary disease in the elderly. Eur J Intern Med. 2014;25(4):320–328.

4.

Phillips M. Method for the collection and assay of volatile organic compounds in breath. Anal Biochem. 1997;247(2):272–278.

5.

Pauling L, Robinson AB, Teranishi R, Cary P. Quantitative analysis of urine vapor and breath by gas-liquid partition chromatography. Proc Natl Acad Sci U S A. 1971;68(10):2374–2376.

6.

Repine JE, Bast A, Lankhorst I. Oxidative stress in chronic obstructive pulmonary disease. Oxidative Stress Study Group. Am J Respir Crit Care Med. 1997;156(2 pt 1):341–357.

7.

MacNee W. Oxidative stress and lung inflammation in airways disease. Eur J Pharmacol. 2001;429(1–3):195–207.

8.

Buszewski B, Kesy M, Ligor T, Amann A. Human exhaled air analytics: biomarkers of diseases. Biomed Chromatogr. 2007;21(6):553–566.

9.

Phillips M, Cataneo RN, Cummin ARC, et al. Detection of lung cancer with volatile markers in the breath. Chest. 2003;123(6):2115–2123.

10.

Darwiche K, Baumbach JI, Sommerwerck U, Teschler H, Freitag L. Bronchoscopically obtained volatile biomarkers in lung cancer. Lung. 2011;189(6):445–452.

11.

Fens N, Roldaan AC, van der Schee MP, et al. External validation of exhaled breath profiling using an electronic nose in the discrimination of asthma with fixed airways obstruction and chronic obstructive pulmonary disease. Clin Exp Allergy. 2011;41(10):1371–1378.

12.

Meyer N, Dallinga JW, Nuss S, et al. Defining adult asthma endotypes by clinical features and patterns of volatile organic compounds in exhaled air. Respir Res. 2014;15(1):136.

13.

Westhoff M, Litterst P, Freitag L, Baumbach JI. Ion mobility spectrometry in the diagnosis of sarcoidosis: results of a feasibility study. J Physiol Pharmacol. 2007;58(suppl 5, pt 2):739–751.

14.

Phillips M, Cataneo RN, Condos R, et al. Volatile biomarkers of pulmonary tuberculosis in the breath. Tuberculosis (Edinb). 2007;87(1):44–52.

15.

Greulich T, Hattesohl A, Grabisch A, et al. Detection of obstructive sleep apnoea by an electronic nose. Eur Respir J. 2013;42(1):145–155.

16.

Incalzi RA, Pennazza G, Scarlata S, et al. Comorbidity modulates non invasive ventilation-induced changes in breath print of obstructive sleep apnea syndrome patients. Sleep Breath. Epub 2014 Oct 17.

17.

Van de Kant KDG, van der Sande LJTM, Jöbsis Q, van Schayck OCP, Dompeling E. Clinical use of exhaled volatile organic compounds in pulmonary diseases: a systematic review. Respir Res. 2012;13:117.

18.

Ibrahim B, Basanta M, Cadden P, et al. Non-invasive phenotyping using exhaled volatile organic compounds in asthma. Thorax. 2011;66(9):804–809.

19.

van Berkel JJBN, Dallinga JW, Möller GM, et al. A profile of volatile organic compounds in breath discriminates COPD patients from controls. Respir Med. 2010;104(4):557–563.

20.

Dragonieri S, Annema JT, Schot R, et al. An electronic nose in the discrimination of patients with non-small cell lung cancer and COPD. Lung Cancer. 2009;64(2):166–170.

21.

Westhoff M, Litterst P, Freitag L, Urfer W, Bader S, Baumbach J-I. Ion mobility spectrometry for the detection of volatile organic compounds in exhaled breath of patients with lung cancer: results of a pilot study. Thorax. 2009;64(9):744–748.

22.

Westhoff M, Litterst P, Madulla S, et al. Differentiation of chronic obstructive pulmonary disease (COPD) including lung cancer patients from health control group by breath analysis using ion mobility spectrometry. Int J Ion Mobil Spectrom. 2010;13:131–139.

23.

Baumbach JI, Eiceman GA. Ion mobility spectrometry: arriving on site and moving beyond a low profile. Appl Spectrosc. 1999;53(9):338A–355A.

24.

Baumbach JI. Process analysis using ion mobility spectrometry. Anal Bioanal Chem. 2006;384(5):1059–1070.

25.

Miller MR, Hankinson J, Brusasco V, et al. Standardisation of spirometry. Eur Respir J. 2005;26(2):319–338.

26.

Jünger M, Bödeker B, Baumbach JI. Peak assignment in multi-capillary column-ion mobility spectrometry using comparative studies with gas chromatography-mass spectrometry for VOC analysis. Anal Bioanal Chem. 2010;396(1):471–482.

27.

Boedeker B, Baumbach I. Analytical description of IMS signals. Int J Ion Mobil Spectrom. 2009;12:103–108.

28.

Boedeker B, Vautz W, Baumbach J. Visualisation of MCC/IMS – data. Int J Ion Mobil Spectrom. 2008;11:77–82.

29.

Kharitonov SA, Yates D, Robbins RA, Logan-Sinclair R, Shinebourne EA, Barnes PJ. Increased nitric oxide in exhaled air of asthmatic patients. Lancet. 1994;343(8890):133–135.

30.

Kharitonov SA, Barnes PJ. Exhaled markers of pulmonary disease. Am J Respir Crit Care Med. 2001;163(7):1693–1722.

31.

Basanta M, Ibrahim B, Dockry R, et al. Exhaled volatile organic compounds for phenotyping chronic obstructive pulmonary disease: a cross-sectional study. Respir Res. 2012;13:72.

32.

Phillips CO, Syed Y, Parthaláin NM, Zwiggelaar R, Claypole TC, Lewis KE. Machine learning methods on exhaled volatile organic compounds for distinguishing COPD patients from healthy controls. J Breath Res. 2012;6(3):036003.

33.

Phillips M, Cataneo RN, Greenberg J, Gunawardena R, Naidu A, Rahbari-Oskoui F. Effect of age on the breath methylated alkane contour, a display of apparent new markers of oxidative stress. J Lab Clin Med. 2000;136(3):243–249.

34.

Phillips M, Cataneo RN, Greenberg J, Gunawardena R, Rahbari-Oskoui F. Increased oxidative stress in younger as well as in older humans. Clin Chim Acta. 2003;328(1–2):83–86.

35.

Moretti M, Phillips M, Abouzeid A, Cataneo RN, Greenberg J. Increased breath markers of oxidative stress in normal pregnancy and in preeclampsia. Am J Obstet Gynecol. 2004;190(5):1184–1190.

36.

Jareño-Esteban JJ, Muñoz-Lucas MÁ, Carrillo-Aranda B, et al. Volatile organic compounds in exhaled breath in a healthy population: effect of tobacco smoking. Arch Bronconeumol. 2013;49(11):457–461.

37.

Filipiak W, Ruzsanyi V, Mochalski P, et al. Dependence of exhaled breath composition on exogenous factors, smoking habits and exposure to air pollutants. J Breath Res. 2012;6(3):036008.

38.

Sibila O, Garcia-Bellmunt L, Giner J, et al. Identification of airway bacterial colonization by an electronic nose in Chronic Obstructive Pulmonary Disease. Respir Med. 2014;108(11):1608–1614.

39.

Agusti A, Calverley PMA, Celli B, et al. Characterisation of COPD heterogeneity in the ECLIPSE cohort. Respir Res. 2010;11:122.

40.

Vestbo J, Agusti A, Wouters EFM, et al. Should we view chronic obstructive pulmonary disease differently after ECLIPSE? A clinical perspective from the study team. Am J Respir Crit Care Med. 2014;189(9):1022–1030.

41.

Phillips C, Mac Parthaláin N, Syed Y, Deganello D, Claypole T, Lewis K. Short-term intra-subject variation in exhaled volatile organic compounds (VOCs) in COPD patients and healthy controls and its effect on disease classification. Metabolites. 2014;4(2):300–318.

Creative Commons License © 2015 The Author(s). This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.