Back to Journals » Clinical Ophthalmology » Volume 11

Effects of 3% diquafosol sodium ophthalmic solution on higher-order aberrations in patients diagnosed with dry eye after cataract surgery

Authors Inoue Y, Ochi S

Received 16 September 2016

Accepted for publication 1 December 2016

Published 23 December 2016 Volume 2017:11 Pages 87—93

DOI https://doi.org/10.2147/OPTH.S122542

Checked for plagiarism Yes

Review by Single-blind

Peer reviewers approved by Dr Amy Norman

Peer reviewer comments 3

Editor who approved publication: Dr Scott Fraser

Yasushi Inoue, Shintarou Ochi

Inoue Eye Clinic, Tamano, Okayama, Japan

Purpose: To evaluate the effects of diquafosol sodium ophthalmic solution 3% (DQS) and artificial tears (AT) on higher-order aberrations (HOAs) in patients with dry eye after cataract surgery.
Design: This was a post hoc analysis of a previously conducted randomized clinical study.
Methods:
Fifty-nine eyes from 42 patients (17 males and 25 females, aged 72.6±8.0 years) with verified or suspected dry eye at 4 weeks after cataract surgery were evaluated. The dry eye patients were randomly assigned to receive DQS or AT for 4 weeks. Tear breakup time (BUT), corneal and conjunctival fluorescein staining scores, and HOAs were analyzed before and after instillation. HOAs were measured consecutively for 10 seconds with a wavefront analyzer. Average HOAs, HOA fluctuations (fluctuation index [FI]) and changes in HOAs (stability index [SI]) were compared within and between the two groups.
Results: After 4 weeks of instillation, BUT significantly increased (P=0.001) compared with preinstillation values in the DQS group, but not in the AT group. This increase in BUT in the DQS group was significantly greater than in the AT group (P=0.014). Corneal and conjunctival fluorescein staining scores after instillation significantly improved compared with preinstillation values in the DQS group (P=0.018). In HOAs, the cornea aberration changed from an upward curve (a sawtooth pattern) to an almost constant value (a stable pattern) in the DQS group, but not in the AT group. In FI and SI, there were no significant changes in either group; however, FI and SI were significantly lower in the DQS group than in the AT group (both, P=0.004).
Conclusion: The dry eye patients after cataract surgery had a visual dysfunction in HOAs. DQS is effective to treat dry eye disease after cataract surgery with improvement of visual function.

Keywords: cataract surgery, dry eye, tear film breakup time, higher-order aberrations, diquafosol ophthalmic solution

Creative Commons License This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.