Back to Journals » Risk Management and Healthcare Policy » Volume 4

Anatomic considerations for central venous cannulation

Authors Bannon M, Heller S, Rivera

Published 13 April 2011 Volume 2011:4 Pages 27—39

DOI https://doi.org/10.2147/RMHP.S10383

Review by Single-blind

Peer reviewer comments 4

Michael P Bannon, Stephanie F Heller, Mariela Rivera
Department of Surgery, Division of Trauma, Critical Care, and General Surgery, Mayo Clinic, Rochester, Minnesota, USA

Abstract: Central venous cannulation is a commonly performed procedure which facilitates resuscitation, nutritional support, and long-term vascular access. Mechanical complications most often occur during insertion and are intimately related to the anatomic relationship of the central veins. Working knowledge of surface and deep anatomy minimizes complications. Use of surface anatomic landmarks to orient the deep course of cannulating needle tracts appropriately comprises the crux of complication avoidance. The authors describe use of surface landmarks to facilitate safe placement of internal jugular, subclavian, and femoral venous catheters. The role of real-time sonography as a safety-enhancing adjunct is reviewed.

Keywords: Internal jugular vein, cannulation, ultrasound, venipuncture

Creative Commons License This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.

Download Article [PDF]  View Full Text [HTML][Machine readable]

 

Readers of this article also read:

Comparative efficacy and safety of local and systemic methotrexate injection in cesarean scar pregnancy

Peng P, Gui T, Liu X, Chen W, Liu Z

Therapeutics and Clinical Risk Management 2015, 11:137-142

Published Date: 27 January 2015

Opioid rotation in patients initiated on oxycodone or morphine: a register study

Ericson L, Ambring A, Björholt I, Dahm P

Journal of Pain Research 2013, 6:379-386

Published Date: 20 May 2013

Methacrylic-based nanogels for the pH-sensitive delivery of 5-Fluorouracil in the colon

Ashwanikumar N, Kumar NA, Nair SA, Kumar GS

International Journal of Nanomedicine 2012, 7:5769-5779

Published Date: 15 November 2012

Cross-linked acrylic hydrogel for the controlled delivery of hydrophobic drugs in cancer therapy

Deepa G, Thulasidasan AK, Anto RJ, Pillai JJ, Kumar GS

International Journal of Nanomedicine 2012, 7:4077-4088

Published Date: 27 July 2012

Corrigendum

Chen ZQ, Liu Y, Zhao JH, Wang L, Feng NP

International Journal of Nanomedicine 2012, 7:1709-1710

Published Date: 30 March 2012

Servant leadership: a case study of a Canadian health care innovator

Vanderpyl TH

Journal of Healthcare Leadership 2012, 4:9-16

Published Date: 16 February 2012

Crystallization after intravitreal ganciclovir injection

Pitipol Choopong, Nattaporn Tesavibul, Nattawut Rodanant

Clinical Ophthalmology 2010, 4:709-711

Published Date: 14 July 2010