Back to Journals » International Journal of Women's Health » Volume 11

Accuracy of fetal anatomy survey in the diagnosis of velamentous cord insertion: a case–control study

Authors Curtin WM, Hill JM, Millington KA, Hamidi OP, Rasiah SS, Ural SH

Received 4 October 2018

Accepted for publication 1 February 2019

Published 11 March 2019 Volume 2019:11 Pages 169—176

DOI https://doi.org/10.2147/IJWH.S189718

Checked for plagiarism Yes

Review by Single-blind

Peer reviewers approved by Dr Cristina Weinberg

Peer reviewer comments 3

Editor who approved publication: Professor Elie Al-Chaer


William M Curtin,1,2 Jennifer M Hill,3,4 Karmaine A Millington,2 Odessa P Hamidi,5 Stephen S Rasiah,5 Serdar H Ural1,6

1Division of Maternal-Fetal Medicine, Department of Obstetrics & Gynecology, Pennsylvania State University College of Medicine, Hershey, PA, USA; 2Department of Pathology & Laboratory Medicine, Pennsylvania State University College of Medicine, Hershey, PA, USA; 3Pennsylvania State University College of Medicine, Hershey, PA, USA; 4Department of Obstetrics & Gynecology, St Francis Hospital and Medical Center, Hartford, CT, USA; 5Department of Obstetrics & Gynecology, Pennsylvania State University College of Medicine, Hershey, PA, USA; 6Department of Radiology, Pennsylvania State University College of Medicine, Hershey, PA, USA

Objective: Our objective was to determine the accuracy of ultrasound at the time of the fetal anatomy survey in the diagnosis of velamentous cord insertion (VCI).
Study design: This retrospective case–control study identified placentas with VCI (cases) and randomly selected placentas with normal placental cord insertion (PCI) (controls) as documented by placental pathology for mothers delivered from 2002 through 2015. Archived ultrasound images for PCI at the time of the fetal anatomy survey were reviewed. Data analysis was by calculation of sensitivity, specificity, and accuracy and their 95% CI for the ultrasound diagnosis of VCI.
Results: The prevalence of VCI was 1.6% of placentas submitted for pathologic examination. There were 122 cases of VCI and 347 controls with normal PCI. The performance criteria calculated for the diagnosis of VCI at the time of fetal anatomy survey were as follows: sensitivity 33.6%; 95% CI: 25.3, 42.7; specificity 99.7%; 95% CI: 98.4, 99.9 and accuracy 82.5; 95% CI: 80.5, 82.9.
Conclusion: The identification of a VCI at the time of fetal anatomy survey is highly specific for the presence of a VCI as documented by placental pathology. The sensitivity in this study was less than expected. Sensitivity could be improved by reducing the number of nonvisualized PCIs, creating an awareness of risk factors for VCI, and obtaining more detailed images in the case of an apparent marginal PCI.

Keywords: velamentous, placental cord insertion, placental pathology, sensitivity, specificity, accuracy

Creative Commons License This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.