-
Medical Devices: Evidence and Research
-
About Dovepress
Open access peer-reviewed scientific and medical journals.
-
Open Access
Dove Medical Press is now a member of the Open Access Initiative
-
An Author's Guide
A guide to help authors get their paper published.
-
Advocacy
Support Open Access and Dove Press
-
Reprints
Promotional Article Monitoring - further details
-
Favored Author Program
Real benefits for authors, including fast-track processing of papers.
Transpedicular screw fixation in the thoracic and lumbar spine with a novel cannulated polyaxial screw system
Original Research
(4269) Views (2656) Full article downloads
Authors: Lutz Weise, Olaf Suess, Thomas Picht, Theodoros Kombos
Published Date October 2008
Volume 2008:1 Pages 33 - 39
DOI: http://dx.doi.org/10.2147/MDER.S3747
Lutz Weise, Olaf Suess, Thomas Picht, Theodoros Kombos
Neurochirurgische Klinik, Charité – Universitätsmedizin Berlin, Berlin, Germany
Objective: Transpedicular screws are commonly and successfully used for posterior fixation in spinal instability, but their insertion remains challenging. Even using navigation techniques, there is a misplacement rate of up to 11%. The aim of this study was to assess the accuracy of a novel pedicle screw system.
Methods: Thoracic and lumbar fusions were performed on 67 consecutive patients for tumor, trauma, degenerative disease or infection. A total of 326 pedicular screws were placed using a novel wire-guided, cannulated, polyaxial screw system (XIA Precision®, Stryker). The accuracy of placement was assessed post operatively by CT scan, and the patients were followed-up clinically for a mean of 16 months.
Results: The total medio-caudal pedicle wall perforation rate was 9.2% (30/326). In 19 of these 30 cases a cortical breakthrough of less than 2 mm occurred. The misplacement rate (defined as a perforation of 2 mm or more) was 3.37% (11/326). Three of these 11 screws needed surgical revision due to neurological symptoms or CSF leakage. There have been no screw breakages or dislocations over the follow up-period.
Conclusion: We conclude that the use of this cannulated screw system for the placement of pedicle screws in the thoracic and lumbar spine is accurate and safe. The advantages of this technique include easy handling without a time-consuming set up. Considering the incidence of long-term screw breakage, further investigation with a longer follow-up period is necessary.
Keywords: spinal instrumentation, pedicle screws, misplacement, pedicle wall perforation
Readers of this article also read:
Radiolucency below the crown of mandibular horizontal incompletely impacted third molars and acute inflammation in men with diabetes
Role of aliskiren in cardio-renal protection and use in hypertensives with multiple risk factors
Functional mobility and balance in community-dwelling elderly submitted to multisensory versus strength exercises
Enucleation following treatment with intravenous pentamidine for Acanthamoeba sclerokeratitis
Erratum
Improvement of adenoviral vector-mediated gene transfer to airway epithelia by folate-modified anionic liposomes
Cumulative clinical experience from over a decade of use of levofloxacin in community-acquired pneumonia: critical appraisal and role in therapy
Erratum
Erratum
- Testimonials
"... I was impressed at the rapidity of publication from submission to final acceptance." Dr Edwin Thrower, PhD, Yale University
- Applications of gold nanoparticles in cancer nanotechnology
- Fungus-mediated biological synthesis of gold nanoparticles: potential in detection of liver cancer
- Gold nanoparticles: From nanomedicine to nanosensing
- Nanocarriers as pulmonary drug delivery systems to treat and to diagnose respiratory and non respiratory diseases




