The effects of lubricant eye drops on visual function as measured by the Inter-blink interval Visual Acuity Decay test
Original Research
(3225) Views (1363) Full article downloads
Author: Gail Torkildsen
Published Date September 2009
Volume 2009:3 Pages 501 - 506
DOI: http://dx.doi.org/10.2147/OPTH.S6225
Gail Torkildsen
Andover Eye Associates, Andover, MA, USA
Objective: The purpose of the current study was to evaluate the effects of two marketed ocular lubricants on the visual decay in dry eye patients using the Inter-blink interval Visual Acuity Decay (IVAD) test.
Methods: This controlled, randomized, double-masked crossover study compared the effects of a polyethylene glycol/propylene glycol-based (PEG/PG) tear and a carboxymethylcellulose sodium (CMC)/glycerin tear on the visual acuity decay between blinks of dry eye patients. At visit 1 (Day 0), baseline IVAD measurements were recorded prior to instillation of a single drop of randomized study medication. IVAD testing was repeated at 15-, 45-, and 90-minutes post-instillation. Reading rate and functional blink rate were also evaluated. At the second visit (Day 7 ± 3), study procedures were repeated using crossover treatment.
Results: Forty-eight (48) subjects with dry eye (61.1 ± 14.8 years old, 79.2% female, 95.8% white) completed the study. Treatment with the PEG/PG-based tear demonstrated statistically significantly longer time to one-line loss of best-corrected visual acuity (BCVA) as determined by the IVAD test at 90 minutes post-instillation compared to the CMC/glycerin tear (P = 0.0365). Measurements of median time at BCVA, reading rate, and functional blink rate were similar for both treatments. Both formulations were well tolerated in the population studied.
Conclusions: Treatment with the PEG/PG-based tear demonstrated statistically significant improved maintenance of visual acuity between blinks at 90 minutes post-instillation compared to the CMC/glycerin tear. This is the first study to demonstrate the ability of an artificial tear to extend visual acuity maintenance between blinks, as measured by the IVAD test.
Keywords: dry eye, visual function, artificial tears, ocular lubricant
- Journal Indexing
See where all the Dove Press journals are indexed
- Interested in being a peer-reviewer?
Click here to register.
- Endophthalmitis: Pathogenesis, clinical presentation, management, and perspectives
- Protection of neurons in the retinal ganglion cell layer against excitotoxicity by the N-acylethanolamine, N-linoleoylethanolamine
- A computer-based anaglyphic system for the treatment of amblyopia
- Treatment of cystoid macular edema with the new-generation NSAID nepafenac 0.1%