skip to content
Dovepress - Open Access to Scientific and Medical Research
View our mobile site

8852

The effect of cotton-based collection methods on eosinophil cationic protein (ECP) concentrations detected in saliva

Original Research

(3361) Views  (689) Full article downloads

Authors: Teck Yee Wong, David Koh, Andrew Wee, Vivian Ng, Yong Tat Koh, et al

Published Date November 2008 Volume 2008:1 Pages 45 - 48
DOI: http://dx.doi.org/10.2147/JAA.S3563

Teck Yee Wong, David Koh, Andrew Wee, Vivian Ng, Yong Tat Koh, Zhenjie Sum, Gerald Koh

Department of Community, Occupational and Family Medicine, Yong Loo Lin School of Medicine, National University of Singapore, Singapore

Background: Salivary eosinophil cationic protein (ECP) level has the potential to be an assessment tool for asthma. Its measurement is not well-established and needs standardization. We studied how passive drool (PD) and two commercial devices, Salivette® (cotton-based device) and Sorbette® (cellulose–cotton-based-device), may affect ECP levels during collection among healthy subjects.

Methods: Study I (n = 10) involved direct sampling of healthy adult subjects with Salivette® and Sorbette®. Study II (n = 33) involved ‘indirect’ sampling of previously collected PD by both devices.

Results: In study I, ECP levels were detected in all PD samples but only in three with Sorbette® and none with Salivette® (collection order: PD, Sorbette® and Salivette®). We changed the order of collection (Salivette®, Sorbette®, PD) and the results were similar (ECP levels detected in all PD samples, three with Sorbette® and only one with Salivette®). In study II, ECP levels in saliva collected by PD was 12.8 μg/L (median) and using Sorbette® and Salivette® were < 2.0 μg/L and 3.4 μg/L respectively (p < 0.01). ECP levels in PD correlated with Sorbette® (rs = 0.79, p < 0.01) and Salivette® (rs = 0.62, p 0.01).

Conclusion: Compared to PD, saliva collected using cotton or cellulose-based collection devices resulted in lower measurable ECP levels.

Keywords: salivary ECP, collection methods








Readers of this article also read:

Use of anticoagulants in elderly patients: practical recommendations
Role of aliskiren in cardio-renal protection and use in hypertensives with multiple risk factors
Cost-effectiveness analysis of intravenous levetiracetam versus intravenous phenytoin for early onset seizure prophylaxis after neurosurgery and traumatic brain injury
Orally disintegrating vardenafil tablets for the treatment of erectile dysfunction: efficacy, safety, and patient acceptability
Perception of risk and benefit in patient-centered communication and care
The relationship between deliberate self-harm behavior, body dissatisfaction, and suicide in adolescents: current concepts
Zinc oxide nanoparticles as selective killers of proliferating cells
Walking just after a meal seems to be more effective for weight loss than waiting for one hour to walk after a meal
Patient preferences for reducing toxicities of treatments for gastrointestinal stromal tumor (GIST)
Cumulative clinical experience from over a decade of use of levofloxacin in community-acquired pneumonia: critical appraisal and role in therapy