The digital aqueous humor outflow meter: an alternative tool for screening of the human eye outflow facility
Original Research
(1385) Views (462) Full article downloads
Authors: Vassilios P Kozobolis, Eleftherios I Paschalis, Nikitas C Foudoulakis, et al
Published Date August 2010
Volume 2010:4 Pages 937 - 945
DOI: http://dx.doi.org/10.2147/OPTH.S11967
Vassilios P Kozobolis, Eleftherios I Paschalis, Nikitas C Foudoulakis, Stavrenia C Koukoula, Georgios LabirisDepartment of Ophthalmology and Eye Institute of Thrace, Democritus University of Thrace, Alexandroupolis, Greece
Purpose: To develop, characterize, and validate a prototype digital aqueous humor outflow tonographer (DAHOM).
Material and methods: The DAHOM was developed, characterized, and validated in three phases. Phase 1 involved construction of the sensor. This was broadly based on the fundamental design of a typical Schiotz tonographer with a series of improvements, including corneal indentation, which was converted to an electrical signal via a linear variable differential transducer, an analog signal which was converted to digital via ADC circuitry, and digital data acquisition and processing which was made possible by a serial port interface. Phase 2 comprised development of software for automated assessment of the outflow facility. Automated outflow facility assessment incorporated a series of fundamental improvements in comparison with traditional techniques, including software-based filtering of ripple noise and extreme variations, rigidity impact analysis, and evaluation of the impact of patient age, central corneal thickness, and ocular axial length. Phase 3 comprised characterization and validation of DAHOM, for which we developed an experimental setup using porcine cadaver eyes. DAHOM’s repeatability was evaluated by means of Cronbach’s alpha and intraclass correlation coefficient. The level of agreement with a standard Schiotz tonographer was evaluated by means of paired t-tests and Bland-Altman analysis in human eyes.
Results: The experimental setup provided the necessary data for the characterization of DAHOM. A fourth order polynomial equation provided excellent fit (R square >0.999). DAHOM demonstrated high repeatability (Cronbach’s alpha ≥0.997; intraclass correlation coefficient ≥0.987) and an adequate level of agreement with a standard Schiotz tonographer.
Conclusions: This study presents the development, characterization, and validation of a prototype digital tonographer. DAHOM demonstrates high repeatability and a sufficient level of agreement with a typical Schiotz tonographer, while its digital design remedies known vulnerabilities of conventional tonographers.
Keywords: glaucoma, tonography, pressure, outflow facility, aqueous humor
- Journal Indexing
See where all the Dove Press journals are indexed
- Interested in being a peer-reviewer?
Click here to register.
- Endophthalmitis: Pathogenesis, clinical presentation, management, and perspectives
- Protection of neurons in the retinal ganglion cell layer against excitotoxicity by the N-acylethanolamine, N-linoleoylethanolamine
- A computer-based anaglyphic system for the treatment of amblyopia
- Treatment of cystoid macular edema with the new-generation NSAID nepafenac 0.1%