skip to content
Dovepress - Open Access to Scientific and Medical Research
View our mobile site

8852

Reticular basement membrane in asthma and COPD: Similar thickness, yet different composition

Original Research

(2933) Views  (609) Full article downloads

Authors: Jeroen JW Liesker, Nick H Ten Hacken, Mieke Zeinstra-Smith, Steven R Rutgers, Dirkje S Postma, et al.

Published Date February 2009 Volume 2009:4 Pages 127 - 135
DOI: http://dx.doi.org/10.2147/COPD.S4639

Jeroen JW Liesker1, Nick H Ten Hacken1, Mieke Zeinstra-Smith2, Steven R Rutgers1, Dirkje S Postma1, Wim Timens2

1Department of Pulmonology; 2Department of Pathology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands

Background: Reticular basement membrane (RBM) thickening has been variably associated with asthma and chronic obstructive pulmonary disease (COPD). Even if RBM thickness is similar in both diseases, its composition might still differ.

Objective: To assess whether RBM thickness and composition differ between asthma and COPD.

Methods: We investigated 24 allergic asthmatics (forced expiratory volume in one second [FEV1] 92% predicted), and 17 nonallergic COPD patients (FEV1 60% predicted), and for each group a control group of similar age and smoking habits (12 and 10 persons, respectively). Snap-frozen sections of bronchial biopsies were stained with hematoxylin/eosin and for collagen I, III, IV, V, laminin and tenascin. RBM thickening was assessed by digital image analysis. Relative staining intensity of each matrix component was determined.

Results: Mean (SD) RBM thickness was not significantly different between asthma and COPD 5.5 (1.3) vs 6.0 (1.8) μm, but significantly larger than in their healthy counterparts, ie, 4.7 (0.9) and 4.8 (1.2) μm, respectively. Collagen I and laminin stained significantly stronger in asthma than in COPD. Tenascin stained stronger in asthma than in healthy controls of similar age, and stronger in COPD controls than in asthma controls (p 0.05).

Conclusion: RBM thickening occurs both in asthma and COPD. We provide supportive evidence that its composition differs in asthma and COPD.

Keywords: reticular basement membrane thickness, reticular basement membrane composition, asthma, biopsy, COPD, remodeling








Readers of this article also read:

Mechanisms of improvement of respiratory failure in patients with COPD treated with NIV
Preferential recruitment of neutrophils by endothelin-1 in acute lung inflammation induced by lipopolysaccharide or cigarette smoke
Efficacy of amoxycillin versus amoxycillin/clavulanate in acute exacerbations of chronic pulmonary obstructive disease in primary care
Measurement of tumor necrosis factor-α, leukotriene B4, and interleukin 8 in the exhaled breath condensate in patients with acute exacerbations of chronic obstructive pulmonary disease
Frequency and clinical relevance of human bocavirus infection in acute exacerbations of chronic obstructive pulmonary disease
Life expectancy and years of life lost in chronic obstructive pulmonary disease: Findings from the NHANES III Follow-up Study
Markers of early disease and prognosis in COPD
Budesonide/formoterol combination in COPD: a US perspective
Development and implementation of treadmill exercise testing protocols in COPD
In search of parsimony: reliability and validity of the Functional Performance Inventory-Short Form
  • Journal Indexing

    See where all the Dove Press journals are indexed

  • Testimonials

    "You do a tremendous job!!" Ruben Restrepo, The University of Texas Health Science Center at San Antonio