skip to content
Dovepress - Open Access to Scientific and Medical Research
View our mobile site

8852

Preparation and characterization of gelatin sponge millispheres injectable through microcatheters

Short Report

(3817) Views  (1519) Full article downloads

Authors: Noboru Yamashita, Katsumi Saitou, Akira Takagi, Atsushi Maruyama

Published Date January 2009 Volume 2009:2 Pages 19 - 25
DOI: http://dx.doi.org/10.2147/MDER.S4798

Noboru Yamashita1, Katsumi Saitou1, Akira Takagi1, Atsushi Maruyama2

1Pharmaceutical Research and Technology Labs, Institute for Technology, Astellas Pharma Inc., 180 Ozumi, Yaizu-shi, Shizuoka-ken 425-0072, Japan; 2Institute for Materials Chemistry and Engineering, Kyushu University, 744-CE11 Motooka, Nishi-ku, Fukuoka 819-0395, Japan

Objective: Millimeter size gelatin sponges are commonly used as an embolic agent for transcatheter arterial embolization (TAE). However the preparation of the fragments is troublesome and carries a risk of contamination. The purpose of this study was to develop gelatin sponge millispheres (GSMs), a convenient and reliable agent, and characterize them in vitro.

Method: The size of GSMs was controlled by modifying the previously reported method to include the use of caprylic triglyceride and isopropanol. Analytical and microbiological tests were conducted to detect impurities (caprylic triglyceride, isopropanol, endotoxins, bacteria, and fungus). The effects of syringe volume (1.0 to 5.0 ml) and contrast media viscosity (1.6 to 13.6 mPa * s) on the in vitro injectability of GSMs through microcatheters of various inner diameters (ID) (0. 43 to 0.53 mm) were examined via in-line pressure monitoring.

Results: The GSMs were found to be water-insoluble particles containing interconnected pores. The short and long diameters of the GSMs were 1.82 ± 0.2 mm and 2.37 ± 0.3 mm, respectively. The results of tests for impurities indicated that GSMs have the general properties necessary for medical devices. The GSMs were successfully injected without clogging through a microcatheter (ID: 0.53 mm) attached to a 1.0 or 2.5 ml syringe.

Conclusion: GSMs have the basic properties and injectability necessary to be considered reliable biomaterials (eg, embolic agents).

Keywords: embolic agents, gelatin sponge millispheres, injectable scaffolds, interconnected pores, microcatheter








Readers of this article also read:

Intra-arterial hepatic chemotherapy for unresectable colorectal liver metastases: a review of medical devices complications in 3172 patients
Radiolucency below the crown of mandibular horizontal incompletely impacted third molars and acute inflammation in men with diabetes
Role of aliskiren in cardio-renal protection and use in hypertensives with multiple risk factors
Next generation drug-eluting stents: focus on bioabsorbable platforms and polymers
Green synthesis and characterization of gelatin-based and sugar-reduced silver nanoparticles
Steroid response pattern and outcome of pediatric idiopathic nephrotic syndrome: a single-center experience in northwest Iran
Cardiometabolic results from an armband-based weight loss trial
Hepatotoxicity due to tocilizumab and anakinra in rheumatoid arthritis: two case reports
Cumulative clinical experience from over a decade of use of levofloxacin in community-acquired pneumonia: critical appraisal and role in therapy
Erratum
  • Testimonials

    "... I was impressed at the rapidity of publication from submission to final acceptance." Dr Edwin Thrower, PhD, Yale University