Back to Journals » Local and Regional Anesthesia » Volume 6
Predicting early epidurals: association of maternal, labor, and neonatal characteristics with epidural analgesia initiation at a cervical dilation of 3 cm or less
Authors Moore AR, Shan WLP, Hatzakorzian R
Received 12 April 2013
Accepted for publication 16 May 2013
Published 28 August 2013 Volume 2013:6 Pages 25—29
DOI https://doi.org/10.2147/LRA.S46686
Checked for plagiarism Yes
Review by Single anonymous peer review
Peer reviewer comments 7
Albert R Moore, William Li Pi Shan, Roupen Hatzakorzian
Department of Anaesthesia, McGill University Health Centre, Royal Victoria Hospital, Montreal, Quebec, Canada
Background: Retrospective studies have associated early epidural analgesia with cesarean delivery, but prospective studies do not demonstrate a causal relationship. This suggests that there are other variables associated with early epidural analgesia that increase the risk of cesarean delivery. This study was undertaken to determine the characteristics associated with early epidural analgesia initiation.
Methods: Information about women delivering at 37 weeks or greater gestation with epidural analgesia, who were not scheduled for cesarean delivery, was extracted from the McGill Obstetric and Neonatal Database. Patients were grouped into those who received epidural analgesia at a cervical dilation of ≤3 cm and >3 cm. Univariable and multivariable logistic regression was used to determine the maternal, neonatal, and labor characteristics that increased the risk of inclusion in the early epidural group.
Results: Of the 13,119 patients analyzed, multivariable regression demonstrated odds ratios (OR) of 2.568, 5.915 and 10.410 for oxytocin augmentation, induction, and dinoprostone induction of labor (P < 0.001). Increasing parity decreased the odds of early epidural analgesia (OR 0.780, P < 0.001), while spontaneous rupture of membranes (OR 1.490) and rupture of membranes before labor commenced (OR 1.288) were also associated with early epidural analgesia (P < 0.001). Increasing maternal weight (OR 1.049, P = 0.002) and decreasing neonatal weight (OR 0.943, P < 0.001) were associated with increasing risk of early epidural analgesia.
Conclusion: Labor augmentation and induction, nulliparity, rupture of membranes spontaneously and before labor starts, increasing maternal weight, and decreasing neonatal weight are associated with early epidural analgesia. Many of these variables are also associated with cesarean delivery.
Keywords: early epidural analgesia, labor, pain, analgesia, outcomes
© 2013 The Author(s). This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.