-
Clinical Ophthalmology
-
About Dovepress
Open access peer-reviewed scientific and medical journals.
-
Open Access
Dove Medical Press is now a member of the Open Access Initiative
-
An Author's Guide
A guide to help authors get their paper published.
-
Advocacy
Support Open Access and Dove Press
-
Reprints
Promotional Article Monitoring - further details
-
Favored Author Program
Real benefits for authors, including fast-track processing of papers.
Modeling spectral sensitivity at low light levels based on mesopic visual performance
Original Research
(1748) Views (542) Full article downloads
Authors: Meri Viikari, Aleksanteri Ekrias, Marjukka Eloholma, Liisa Halonen
Published Date March 2008
Volume 2008:2(1) Pages 173 - 185
DOI: http://dx.doi.org/10.2147/OPTH.S2414
Meri Viikari, Aleksanteri Ekrias, Marjukka Eloholma, Liisa Halonen
Lighting Laboratory, Helsinki University of Technology, Finland
Abstract: The spectral sensitivity of the eye at low light levels, ie, mesopic conditions, is determined by the rod and cone photoreceptors of the retina operating together in varying degree as adaptation luminance shifts between the scotopic and photopic. Thus mesopic spectral sensitivity is different from photopic, where only cones contribute to vision. There are definite needs for a practical system of mesopic photometry to be used in assessing light at low light levels, especially in road and other outdoor lighting applications. However, neither of the recently proposed systems of mesopic photometry, the MOVE-model or the X-model, is found satisfactory by common consent of the lighting community. The most active debate has considered the upper luminance limit of the mesopic region, which is regarded to be too high for the MOVE-model and too low for the X-model. The present paper proposes a new modified MOVE-model whose upper luminance limit is adjusted to meet the actual road and street lighting luminance values measured in different weather conditions. The paper compares the MOVE-model, X-model, and the proposed modified MOVE-model with three independent visual performance data sets provided by different European universities. Based on the comparison, recommendations are given for future actions towards internationally accepted practice for mesopic photometry.
Keywords: spectral sensitivity, mesopic, visual performance, mesopic model, photometry, night-time driving
- Journal Indexing
See where all the Dove Press journals are indexed
- Interested in being a peer-reviewer?
Click here to register.
- Endophthalmitis: Pathogenesis, clinical presentation, management, and perspectives
- Protection of neurons in the retinal ganglion cell layer against excitotoxicity by the N-acylethanolamine, N-linoleoylethanolamine
- A computer-based anaglyphic system for the treatment of amblyopia
- Treatment of cystoid macular edema with the new-generation NSAID nepafenac 0.1%




