Back to Journals » Clinical Ophthalmology » Volume 4

Measurement of treatment compliance using a medical device for glaucoma patients associated with intraocular pressure control: a survey

Authors Nordmann J, Baudouin C, Renard J, Denis P, Lafuma A, Laurendeau C, Jeanbat V, Berdeaux G

Published 20 July 2010 Volume 2010:4 Pages 731—739

DOI https://doi.org/10.2147/OPTH.S11799

Review by Single anonymous peer review

Peer reviewer comments 3



Jean-Philippe Nordmann1, Christophe Baudouin1, Jean-Paul Renard2, Philippe Denis3, Antoine Lafuma4, Caroline Laurendeau4, Viviane Jeanbat4, Gilles Berdeaux5,6

1Hôpital des Quinzes-Vingt, Paris, France; 2Hôpital du Val de Grâce, Paris, France; 3Hôpital Edouard Herriot, Lyon, France; 4Cemka, Bourg-la-Reine, France; 5Alcon France, Rueil-Malmaison, France; 6Conservatoire National des Arts et Métiers, Paris, France

Objective: To identify and characterize treatment compliance profiles of glaucoma patients and evaluate the association with intraocular pressure (IOP).

Methods: A computerized device (Travalert®) that recorded daily instillation times and eye-drop counts was given for 3 months. Patients were declared compliant when at least 2 drops were instilled per day. Compliance rates were calculated for weekdays and weekends, separately, over 8 consecutive weeks. A principal components analysis (PCA) was followed by an ascendant hierarchical classification (AHC) to identify compliance groups.

Results: 140 patients were recruited (mean age 65.5 years; 51.8% female) of whom 83.6% had primary open-angle glaucoma with mean IOP 23.9 mmHg before Travalert® use. 60.7% were treated with DuoTrav® (travoprost timolol fixed combination) and 39.3% with ­travoprost. The PCA identified two axes (compliance and treatment weeks). The AHC identified 3 ­compliance groups: ‘high’ (56.6%, approx. 80% compliance), ‘medium’ (21.2%, approx. 50% compliance), and ‘low’ (22.1%, approx. 20% compliance). Demographics and glaucoma parameters did not predict low compliance. Final mean IOP was 16.1 mmHg, but higher in the low compliance group (17.7 mmHg, P = 0.02).

Conclusions: Compliance measurement by a medical device showed compliance rates <80% by 50% (approx.) of patients, significantly impacting IOP control. No demographic or glaucoma variable was associated with low compliance.

Keywords: glaucoma, compliance, efficacy, intraocular pressure control

Creative Commons License © 2010 The Author(s). This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.