Influence of light curing and sample thickness on microhardness of a composite resin
Original Research
(2430) Views (1228) Full article downloads
Authors: Flávio HB Aguiar, Kelly RM Andrade, Débora AN Leite Lima, Gláucia MB Ambrosano, et al.
Published Date May 2009
Volume 2009:1 Pages 21 - 25
DOI: http://dx.doi.org/10.2147/CCIDEN.S4863
Flávio HB Aguiar1, Kelly RM Andrade1, Débora AN Leite Lima1, Gláucia MB Ambrosano2, José R Lovadino1
1Department of Restorative Dentistry; 2Department of Social Dentistry/Statistics, Piracicaba Dental School, State University of Campinas, SP, Brazil
Abstract: The aim of this in vitro study was to evaluate the influence of light-curing units and different sample thicknesses on the microhardness of a composite resin. Composite resin specimens were randomly prepared and assigned to nine experimental groups (n = 5): considering three light-curing units (conventional quartz tungsten halogen [QTH]: 550 mW/cm2 – 20 s; high irradiance QTH: 1160 mW/cm2 – 10 s; and light-emitting diode [LED]: 360 mW/cm2 – 40 s) and three sample thicknesses (0.5 mm, 1 mm, and 2 mm). All samples were polymerized with the light tip 8 mm away from the specimen. Knoop microhardness was then measured on the top and bottom surfaces of each sample. The top surfaces, with some exceptions, were almost similar; however, in relation to the bottom surfaces, statistical differences were found between curing units and thicknesses. In all experimental groups, the 0.5-mm-thick increments showed microhardness values statistically higher than those observed for 1- and -2-mm increments. The conventional and LED units showed higher hardness mean values and were statistically different from the high irradiance unit. In all experimental groups, microhardness mean values obtained for the top surface were higher than those observed for the bottom surface. In conclusion, higher levels of irradiance or thinner increments would help improve hybrid composite resin polymerization.
Keywords: photo-polymerization, light-curing distance, light-curing units, composite resin, composite thickness, microhardness
Readers of this article also read:
Radiolucency below the crown of mandibular horizontal incompletely impacted third molars and acute inflammation in men with diabetes
Berberine: metabolic and cardiovascular effects in preclinical and clinical trials
Current practicality of nanotechnology in dentistry. Part 1: Focus on nanocomposite restoratives and biomimetics
Critical appraisal of the role of glucosamine and chondroitin in the management of osteoarthritis of the knee
Ego mechanisms of defense are associated with patients’ preference of treatment modality independent of psychological distress in end-stage renal disease
Can a gentamicin-specific chart reduce neonatal medication errors?
Morgellons disease: Analysis of a population with clinically confirmed microscopic subcutaneous fibers of unknown etiology
Nephroprotective action of glycosaminoglycans: why the pharmacological properties of sulodexide might be reconsidered
Dashboards in neonatology
- Testimonials
"You do a tremendous job!!" Ruben Restrepo, The University of Texas Health Science Center at San Antonio
- Current practicality of nanotechnology in dentistry. Part 1: Focus on nanocomposite restoratives and biomimetics
- Bone resorption in incompletely impacted mandibular third molars and acute pericoronitis
- Radiolucency below the crown of mandibular horizontal incompletely impacted third molars and acute inflammation in men with diabetes
- Periosteoplasty for covering gingival recessions: Clinical results