Hybrid microincision vitrectomy surgery combined with 20-gauge silicone cannulas for use with 20-gauge horizontal scissors in diabetic tractional retinal detachment

Authors Yamada K, Maeno T, Yamada M

Received 9 April 2013

Accepted for publication 4 June 2013

Published 1 August 2013 Volume 2013:7 Pages 1559—1563

DOI https://doi.org/10.2147/OPTH.S46486

Checked for plagiarism Yes

Review by Single anonymous peer review

Peer reviewer comments 4



Keiko Yamada,1 Takatoshi Maeno,2 Mitsunori Yamada3

1Department of Ophthalmology, Kyoto Prefectural University of Medicine, Kyoto, Japan; 2Department of Ophthalmology, Toho University Sakura Medical Center, Chiba, Japan; 3Yamada Eye Clinic, Tokushima, Japan


Purpose: To verify the utility and preliminary safety of a 20-gauge silicone cannula for use with 20-gauge horizontal scissors delamination during microincision vitrectomy surgery (MIVS).
Methods: Thirty-eight eyes in 35 consecutive patients with diabetic tractional retinal detachment, who underwent MIVS between April 2010 and March 2012 and were followed for 3–24 months, were retrospectively assessed using a chart review. Twenty-gauge scissors delamination through a silicone cannula, with an additional 20-gauge port as a hybrid, was primarily selected when treating thick and rigid fibrovascular membranes, including fluctuating vessels over the detached retina near the macula. The main outcome measures included the proportion of patients treated with this hybrid method, the postoperative visual acuity, and the incidence of complications.
Results: Compared with the 26 eyes treated with MIVS only, 12 eyes (32%) required a hybrid technique with the use of 20-gauge instruments through a silicone cannula in addition to MIVS. Two patients underwent additional surgery. Temporary silicone oil tamponade was performed in one case of retinotomy and one case of schizophrenia. The mean visual acuity (logarithm of the minimum angle of resolution [logMAR]) improved from 1.43 ± 0.85 to 0.72 ± 0.47 at the last follow-up visit. No patients exhibited worsening of their visual acuity postoperatively. No sclerotomy-related complications were recorded during the intraoperative or postoperative periods.
Conclusion: Hybrid MIVS combined with a 20-gauge silicone cannula for use with 20-gauge horizontal scissors in diabetic tractional retinal detachment eyes is useful and safe due to the reduced risk of sclerotomy-related retinal breaks. This procedure is a reasonable option when performing complex surgery for diabetic vitrectomy.

Keywords: small gauge vitrectomy, cannulated vitrectomy system, cutter delamination, scissor delamination, 20-gauge instruments, sclerotomy retinal tears

Creative Commons License © 2013 The Author(s). This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.