Back to Journals » Clinical Ophthalmology » Volume 7

Femtosecond lenticule extraction for correction of myopia: a 6 month follow-up study

Authors Demirok A, Agca A, Ozgurhan EB, Bozkurt E, Celik U, Demircan A, Guleryuz NB, Cankaya Kİ, Yilmaz OF

Received 14 March 2013

Accepted for publication 11 April 2013

Published 7 June 2013 Volume 2013:7 Pages 1041—1047

DOI https://doi.org/10.2147/OPTH.S45225

Checked for plagiarism Yes

Review by Single anonymous peer review

Peer reviewer comments 4



Ahmet Demirok,1 Alper Agca,2 Engin Bilge Ozgurhan,2 Ercument Bozkurt,2 Ugur Celik,2 Ali Demircan,2 Nimet Burcu Guleryuz,2 Kadir Ilker Cankaya,2 Omer Faruk Yilmaz3

1Department of Ophthalmology, Medeniyet University, Istanbul, Turkey; 2Beyoglu Eye Training and Research Hospital, Istanbul, Turkey, 3Private Practice, Istanbul, Turkey

Aims: To report our initial experience with femtosecond lenticule extraction (FLEX) compared with femtosecond laser-assisted in situ keratomileusis (LASIK).
Settings and design: This was a prospective pilot study carried out at the Refractive Surgery Department of the Beyoglu Eye Training and Research Hospital, Istanbul, Turkey.
Materials and methods: Surgery was performed on both eyes of 14 consecutive patients with myopia or myopic astigmatism. Patients underwent FLEX in one eye and femtosecond LASIK (FemtoLASIK) in the other eye. The primary outcome was based on uncorrected distance visual acuity, corrected distance visual acuity, and spherical equivalent of the subjective manifest refraction, at 1 week, 1 month, and 6 months postsurgery. Statistical analyses were performed using PAWS Statistics 18. Unpaired Student’s t-test was used to compare the groups.
Results: During the last follow-up visit (6 months postsurgery), the mean spherical was −0.37 ± 0.60 diopters (D) (range −1.00 to 0.50) (P < 0.001) and −0.25 ± 0.41 D (range −0.88 to 0.12 D) (P < 0.001) in the FLEX and FemtoLASIK eyes, respectively. The spherical was within ± 0.50 D of the intended correction in ten (72%) of the FLEX eyes and 12 (86%) of the FemtoLASIK eyes (P > 0.05). No complications occurred during surgery or the postoperative period.
Conclusion: FLEX is a safe, effective, and predictable procedure for surgical correction of myopia. Refractive results were stabilized within the first postoperative week, and visual acuities were stabilized within the first month, comparable to FemtoLASIK.

Keywords: FLEX, femtosecond laser-assisted in situ keratomileusis

Creative Commons License © 2013 The Author(s). This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.