Back to Journals » Clinical Ophthalmology » Volume 7

Essential opaque bubble layer elimination with novel LASIK flap settings in the FS200 Femtosecond Laser

Authors Kanellopoulos AJ , Asimellis G

Received 6 February 2013

Accepted for publication 4 March 2013

Published 19 April 2013 Volume 2013:7 Pages 765—770

DOI https://doi.org/10.2147/OPTH.S43723

Checked for plagiarism Yes

Review by Single anonymous peer review

Peer reviewer comments 2



Video abstract presented by A John Kanellopoulos and George Asimellis

Views: 802

A John Kanellopoulos,1,2 George Asimellis1

1Laservision.gr Eye Institute, Athens, Greece; 2New York University School of Medicine, New York, NY, USA

Background: The purpose of this study is to evaluate the extent and incidence of opaque bubble layer (OBL) using laser-assisted in situ keratomileusis (LASIK) flaps created with the Alcon/WaveLight® FS200 femtosecond laser as a result of a recent change in flap programming parameters aiming to reduce further the incidence and extent of OBL.
Methods: Intraoperative digital images of flaps from 36 consecutive patients (72 eyes) subjected to bilateral femtosecond-assisted LASIK were analyzed using a proprietary computerized technique. The incidence and extent of OBL was measured and reported as a percentage of the entire flap area. Flap creation was performed with a 1.7 mm wide canal, implemented as an updated design intended to reduce the extent of OBL (group A). The same OBL parameters were investigated and compared in an age-matched and procedure-matched patients in whom the previous standard setting of a 1.3 mm wide canal was implemented (group B).
Results: In group A, the average extent of OBL was 3.69% of the flap area (range 0%–11.34%). In group B, the respective values were 6.06% (range 0%–20.24%). We found the difference to be statistically significant (one-tailed P = 0.00452).
Conclusion: This study suggests that there is a significant reduction in the incidence and extent of OBL when novel LASIK flap ventilation canal parameters of width and spot line separation are used.

Keywords: femtosecond laser flap, bladeless laser-assisted in situ keratomileusis, opaque bubble layer, Alcon/WaveLight FS200, spot line separation

Creative Commons License © 2013 The Author(s). This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution - Non Commercial (unported, v3.0) License. By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms.