-
Medical Devices: Evidence and Research
-
About Dovepress
Open access peer-reviewed scientific and medical journals.
-
Open Access
Dove Medical Press is now a member of the Open Access Initiative
-
An Author's Guide
A guide to help authors get their paper published.
-
Advocacy
Support Open Access and Dove Press
-
Reprints
Promotional Article Monitoring - further details
-
Favored Author Program
Real benefits for authors, including fast-track processing of papers.
Epi-aortic Doppler measurement of cardiac output in univentricular connection
Original Research
(3442) Views (852) Full article downloads
Authors: Ad J J C Bogers, Martin van den Burg, Ronald Schepp, Jan Klein
Published Date February 2009
Volume 2009:2 Pages 27 - 29
DOI: http://dx.doi.org/10.2147/MDER.S4666
Ad J J C Bogers1, Martin van den Burg1,2, Ronald Schepp2, Jan Klein2
1Department of Cardiothoracic Surgery; 2Department of Anesthesiology, Thoraxcentre, Erasmus University Medical Centre, Rotterdam, The Netherlands
Background: In the initial postoperative period after a Fontan-type operation for a univentricular circulation, cardiac output information is important, but cannot be provided by conventional methods due to the surgical reconstruction of the heart. In this regard we investigated the feasibility of epi-aortic Doppler measurements in order to calculate cardiac output.
Methods: Epi-aortic cardiac output measurement was compared with Fick measurements as the gold standard in eight patients with a univentricular circulation after a Fontan-type operation.
Results: The mean diameter of the aorta by epi-aortic measurement was 18 mm (range 14 to 25), by angiography 17 mm (range 10 to 24), correlation coefficient 0.88 (p < 0.05). The mean cardiac output by epi-aortic measurement was 2.8 l.min−1 (range 1.2 to 6.3), by the Fick calculations 1.8 l.min−1 (range 0.8 to 5.0). The correlation coefficient for cardiac output data in aortic diameters up to 20 millimeter in diameter was 0.55 (p < 0.05).
Conclusions: Epi-aortic Doppler measurement of cardiac output after Fontan type reconstructions could be applied in aortas up to 20 millimeter in diameter. A reasonable correlation with Fick calculations was found. This was supported by Bland–Altman plotting. The method is intrinsically invasive, but application and removal of the device were easy and no complications related to the system were observed. An important restriction is the often present abnormal anatomy, either congenitally or after surgery.
Keywords: cardiac output, Fontan circulation, epi-aortic Doppler, extravascular Doppler
Readers of this article also read:
Development of a framework for pneumatic device selection for lymphedema treatment
Health literacy and health seeking behavior among older men in a middle-income nation
Retinal nerve fiber layer evaluation in multiple sclerosis with spectral domain optical coherence tomography
Erratum
Perception of risk and benefit in patient-centered communication and care
The relationship between deliberate self-harm behavior, body dissatisfaction, and suicide in adolescents: current concepts
Zinc oxide nanoparticles as selective killers of proliferating cells
Erratum
Cumulative clinical experience from over a decade of use of levofloxacin in community-acquired pneumonia: critical appraisal and role in therapy
- Testimonials
"... I was impressed at the rapidity of publication from submission to final acceptance." Dr Edwin Thrower, PhD, Yale University
- Applications of gold nanoparticles in cancer nanotechnology
- Fungus-mediated biological synthesis of gold nanoparticles: potential in detection of liver cancer
- Gold nanoparticles: From nanomedicine to nanosensing
- Nanocarriers as pulmonary drug delivery systems to treat and to diagnose respiratory and non respiratory diseases




