-
Clinical Interventions in Aging
-
About Dovepress
Open access peer-reviewed scientific and medical journals.
-
Open Access
Dove Medical Press is now a member of the Open Access Initiative
-
An Author's Guide
A guide to help authors get their paper published.
-
Advocacy
Support Open Access and Dove Press
-
Reprints
Promotional Article Monitoring - further details
-
Favored Author Program
Real benefits for authors, including fast-track processing of papers.
Effect of multiple impacts on protective properties of external hip protectors
Original Research
(2150) Views (449) Full article downloads
Authors: Tatjana Bulat, Shawn Applegarth, Stuart Wilkinson, Shirley G Fitzgerald, Shahbaz Ahmed, Patricia Quigley
Published Date October 2008
Volume 2008:3(3) Pages 567 - 571
DOI: http://dx.doi.org/10.2147/CIA.S2529
Tatjana Bulat1, Shawn Applegarth1, Stuart Wilkinson2, Shirley G Fitzgerald1, Shahbaz Ahmed1, Patricia Quigley1
1VISN 8 Patient Safety Center of Inquiry, Tampa, FL, USA; 2University of South Florida Department of Mechanical Engineering, Tampa, FL, USA
Abstract: A variety of external hip protectors are available on the market but no standards for their performance exist and it is unknown if their properties change after repeated fall impacts. The purpose of this study was to determine if protective properties change in different types of new (unused) hip protectors after repeated, simulated falls. Five hip protector brands were chosen to represent different products available on the market and the two mechanisms employed in reducing the force of an impact (shunting or absorbing). Ten pairs of each type (20 pads for each brand) were tested using a 1.8-m Instron Dynatup 9250 HV vertical impact testing tower. The impact testing system was specifically designed for this study by creating a simulated trochanter to provide more accurately a impact area similar to that of a real hip bone. The hip protectors were impacted once a day for 3 consecutive days. Repeated impacts demonstrated the pads’ decreased ability to either absorb or shunt force in all types of hip protectors. However, the mean forces were still in the protective range (force below fracture threshold of 3100 N) for 3 of the 5 brands tested after 3 impacts. The protective properties of external hip protectors do degrade after repeated impacts. The degree of degradation differs from brand to brand. Regardless of type, most pads were still able to bring the force of impact below the fracture threshold of 3100 N. Future studies need to address the issue of durability of different types/brands of hip protectors after repeated laundering and fall impacts to determine when should they be replaced. Additionally, a national or international standard needs to be developed against which the performance of different brands of hip protectors can be compared.
Keywords: hip protectors, fall impacts, protective properties, hip fracture
Other articles by Dr Tatjana Bulat
Effect of a group-based exercise program on balance in elderly- Have an opinion about one of our articles?
We encourage you to write a Letter to the Editor
- Journal Indexing
See where all the Dove Press journals are indexed
- Testimonials
"You do a tremendous job!!" Ruben Restrepo, The University of Texas Health Science Center at San Antonio
- American Acne and Rosacea Society
The American Acne and Rosacea Society (AARS), is a 501(c)(6) non-profit organization dedicated to elevating the understanding and treatment of acne and rosacea.
- Radio electric asymmetric brain stimulation in the treatment of behavioral and psychiatric symptoms in Alzheimer disease
- Eggshell membrane: A possible new natural therapeutic for joint and connective tissue disorders. Results from two open-label human clinical studies
- Comparison of two treatments for coxarthrosis: local hyperthermia versus radio electric asymmetrical brain stimulation
- The cognitive impact of anticholinergics: A clinical review




