-
International Journal of Nanomedicine
-
About Dovepress
Open access peer-reviewed scientific and medical journals.
-
Open Access
Dove Medical Press is now a member of the Open Access Initiative
-
An Author's Guide
A guide to help authors get their paper published.
-
Advocacy
Support Open Access and Dove Press
-
Reprints
Promotional Article Monitoring - further details
-
Favored Author Program
Real benefits for authors, including fast-track processing of papers.
Dose comparison of ultrasonic transdermal insulin delivery to subcutaneous insulin injection
Original Research
(2028) Views (517) Full article downloads
Authors: Eun-Joo Park, Jeff Dodds, Nadine Barrie Smith
Published Date October 2008
Volume 2008:3(3) Pages 335 - 341
DOI: http://dx.doi.org/10.2147/IJN.S2761
Eun-Joo Park1, Jeff Dodds2, Nadine Barrie Smith3
1Department of Bioengineering, 2Animal Resource Program, 3Graduate Program in Acoustics, The Pennsylvania State University, University Park, PA, USA
Abstract: Prior studies have demonstrated the effectiveness of noninvasive transdermal insulin delivery using a cymbal transducer array. In this study the physiologic response to ultrasound mediated transdermal insulin delivery is compared to that of subcutaneously administered insulin. Anesthetized rats (350–550 g) were divided into four groups of four animals; one group representing ultrasound mediated insulin delivery and three representing subcutaneously administered insulin (0.15, 0.20, and 0.25 U/kg). The cymbal array was operated for 60 minutes at 20 kHz with 100 mW/cm2 spatial-peak temporal-peak intensity and a 20% duty cycle. The blood glucose level was determined at the beginning of the experiment and, following insulin administration, every 15 minutes for 90 minutes for both the ultrasound and injection groups. The change in blood glucose from baseline was compared between groups. When administered by subcutaneous injection at insulin doses of 0.15 and 0.20 U/kg, there was little change in the blood glucose levels over the 90 minute experiment. Following subcutaneous administration of insulin at a dose of 0.25 U/kg, blood glucose decreased by 190 ± 96 mg/dl (mean ± SD) at 90 minutes. The change in blood glucose following ultrasound mediated insulin delivery was −262 ± 40 mg/dl at 90 minutes. As expected, the magnitude of change in blood glucose between the three injection groups was dependant on the dose of insulin administered. The change in blood glucose in the ultrasound group was greater than that observed in the injection groups suggesting that a higher effective dose of insulin was delivered.
Keywords: ultrasound, intensity, drug delivery, insulin, injections
- Have an opinion about one of our articles?
We encourage you to write a Letter to the Editor
- Interested in being a peer-reviewer?
Click here to register.
- Display new articles on your site
Use our widget to show articles on your own site
- Applications of gold nanoparticles in cancer nanotechnology
- Fungus-mediated biological synthesis of gold nanoparticles: potential in detection of liver cancer
- Gold nanoparticles: From nanomedicine to nanosensing
- Nanocarriers as pulmonary drug delivery systems to treat and to diagnose respiratory and non respiratory diseases




