Comparison of intraocular pressure measurements with the portable PT100 noncontact tonometer and Goldmann applanation tonometry
Original Research
(1982) Views (2036) Full article downloads
Authors: Sarwat Salim, Daniel J Linn, James R Echols II, Peter A Netland
Published Date May 2009
Volume 2009:3 Pages 341 - 344
DOI: http://dx.doi.org/10.2147/OPTH.S5537
Sarwat Salim, Daniel J Linn, James R Echols II, Peter A Netland
Hamilton Eye Institute, University of Tennessee Health Science Center, Memphis, TN, USA
Purpose: Noncontact tonometers are useful when regulations preclude use of contact tonometers by medical students and other nonophthalmologists. Our study compared the measurements by the portable, noncontact tonometer (PT100) with Goldmann applanation tonometry (GAT).
Methods: This was a prospective study of 98 eyes from 98 patients. Intraocular pressure (IOP) was measured by GAT and the PT100 (Reichert, Buffalo, NY).
Results: Mean IOP measurements showed no significant differences in measurements performed by the two tonometers (P = 0.64). Measurements by the two tonometers were in agreement by ≤3 mmHg in 92.8% of eyes. Linear regression analysis of PT100 vs GAT measurements revealed a slope of 0.98 with r2 = 0.58. Bland–Altman analysis showed a mean difference of measurements by GAT and PT100 of -0.3 mmHg with two standard deviation = 7.1 mmHg.
Conclusion: The portable noncontact PT100 tonometer provides IOP measurements comparable to GAT within the normal range of IOP.
Keywords: applanation tonometer, intraocular pressure, noncontact tonometry
Other articles by Dr Peter Netland
Trabeculectomy versus Ahmed Glaucoma Valve implantation in neovascular glaucoma- Journal Indexing
See where all the Dove Press journals are indexed
- Interested in being a peer-reviewer?
Click here to register.
- Endophthalmitis: Pathogenesis, clinical presentation, management, and perspectives
- Protection of neurons in the retinal ganglion cell layer against excitotoxicity by the N-acylethanolamine, N-linoleoylethanolamine
- A computer-based anaglyphic system for the treatment of amblyopia
- Treatment of cystoid macular edema with the new-generation NSAID nepafenac 0.1%