Comparison of artifact generation with catheter bending using different PS-OCT approaches
Original Research
(3302) Views (776) Full article downloads
Authors: Kathy Zheng, Christopher Rashidifard, Bin Liu, Mark Brezinski
Published Date May 2009
Volume 2009:2 Pages 49 - 54
DOI: http://dx.doi.org/10.2147/RMI.S4389
Kathy Zheng1, Christopher Rashidifard1, Bin Liu1,2, Mark Brezinski1,2
1Center for Optical Coherence Tomography and Optical Physics, Department of Orthopedic Surgery, Brigham and Women’s Hospital, Boston, MA, USA; 2Harvard Medical School, Boston, MA, USA
Abstract: Optical coherence tomography (OCT) is a promising biomedical imaging tool for detecting pathology at a micron scale. In addition to performing structural imaging, other adjuvant techniques are available with OCT. In particular, polarization-sensitive optical coherence tomography (PS-OCT) can be used, either through a single or dual detector approach, to assess collagen concentration and organization. In this paper, we compare the ability of single and dual detector PS-OCT with respect to catheter bending artifacts. It was found that even severe catheter bending resulted in no significant difference in quantitative birefringence measurement with the single detector approach. However, when the dual detector approach was examined, catheter bending resulted in a highly significant change in backreflection intensity. This paper raises questions as to the appropriateness of dual detector PS-OCT for performing catheter and endoscope based birefringence assessments.
Keywords: Optical coherence tomography, polarization, single detector, endoscopic imaging
- Testimonials
"... I was impressed at the rapidity of publication from submission to final acceptance." Dr Edwin Thrower, PhD, Yale University
- Imaging of peripheral vascular disease
- Capillary telangiectasia mimicking an active inflammatory MS-lesion in repetitive cMRIs
- Comparison of a new PillCam™ SB2 video capsule versus the standard PillCam™ SB for detection of small bowel disease
- F-18 fluorodeoxyglucose (FDG) positron emission tomography (PET)-positive parotid incidentaloma: Prevalence and clinical significance