-
International Journal of Chronic Obstructive Pulmonary Disease
-
About Dovepress
Open access peer-reviewed scientific and medical journals.
-
Open Access
Dove Medical Press is now a member of the Open Access Initiative
-
An Author's Guide
A guide to help authors get their paper published.
-
Advocacy
Support Open Access and Dove Press
-
Reprints
Promotional Article Monitoring - further details
-
Favored Author Program
Real benefits for authors, including fast-track processing of papers.
Can dead space fraction predict the length of mechanical ventilation in exacerbated COPD patients?
Original Research
(2310) Views (667) Full article downloads
Authors: Raymond Farah, Nicola Makhoul
Published Date November 2009
Volume 2009:4 Pages 437 - 441
DOI: http://dx.doi.org/10.2147/COPD.S7509
Raymond Farah1, Nicola Makhoul2
1Specialist in Internal Medicine and Nephrology, Department of Internal Medicine B, Ziv Medical Center, Safed-Israel; 2Director of Respiratory Intensive Care Unit, Western Galilee Hospital, Nahariya, Israel
Background: Chronic obstructive pulmonary disease (COPD) is a condition in which there is limited airflow during expiration (exhaling, or breathing out) that is not fully reversible and usually worsens over time. The disease is estimated to kill more than 100,000 Americans each year, and costs related to care of patients with COPD are significant. Physiologically, COPD represents a disruption in ventilation and in the exchange of gases in the lungs. Laboratory tests indicate elevated CO2 levels, gradual reduction of the levels of oxygen and pH in arterial blood, and a consequent rise in the dead space fraction (DSF) of the lungs.
Objective: Patients with COPD exacerbation represent a large portion of those artificially ventilated. In an attempt to develop a prognostic tool for length of treatment, we compared the proportion of DSF to the length of mechanical ventilation (MV).
Methods: This study included 73 patients admitted to the intensive care unit (ICU) where they received MV due to exacerbation of COPD. Each patient’s arterial blood gases (ABG) were measured upon admission. PeCO2 was tested using a Datex S/5 instrument. Subsequently, DSF was calculated using the Bohr equation. Statistical data was analyzed using SPSS software.
Results: Patients included in the study were ventilated from 6 to 160 hours (average 40 ± 47). In addition to ABG measurements, PeCO2 (expired CO2) levels were measured and DSF calculated for each patient. DSF values varied from 0.21 to 0.76 (average 0.119 ± 0.489). No correlation was found between DSF and length of artificial ventilation.
Conclusion: Evaluation of DSF does not provide a factor in estimating the length of treatment for patients with acute respiratory failure due to COPD exacerbation.
Keywords: dead space, weaning, mechanical ventilation, COPD
- Journal Indexing
See where all the Dove Press journals are indexed
- Testimonials
"You do a tremendous job!!" Ruben Restrepo, The University of Texas Health Science Center at San Antonio
- Clinical effectiveness of the Respimat® inhaler device in managing chronic obstructive pulmonary disease: evidence when compared with other handheld inhaler devices
- Chronic obstructive pulmonary disease as an independent risk factor for cardiovascular morbidity
- The pathophysiology of bronchiectasis
- Exacerbation rate, health status and mortality in COPD – a review of potential interventions




